<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
		>

<channel>
	<title>NDT Inspect &#8211; NDT Career and Community Portal | holld | Activity</title>
	<link>https://ndtinspect.com/members/holld/activity/</link>
	<atom:link href="https://ndtinspect.com/members/holld/activity/feed/" rel="self" type="application/rss+xml" />
	<description>Activity feed for holld.</description>
	<lastBuildDate>Sun, 12 Apr 2026 08:47:45 +0500</lastBuildDate>
	<generator>https://buddypress.org/?v=2.21.0</generator>
	<language>en-US</language>
	<ttl>30</ttl>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>2</sy:updateFrequency>
		
								<item>
				<guid isPermaLink="false">ec33b6e63f9f3b7a5d562b8c080f8a32</guid>
				<title>holld posted an update in the group Corrosion Mapping (CM): </title>
				<link>https://ndtinspect.com/news-feed/p/16436/</link>
				<pubDate>Fri, 27 May 2022 15:33:43 +0500</pubDate>

				
									<slash:comments>0</slash:comments>
				
							</item>
					<item>
				<guid isPermaLink="false">d097de26f3b6b8d4655ce97845989389</guid>
				<title>holld started the discussion High temperature corrosion mapping utilizing PAUT method in the forum Corrosion Mapping</title>
				<link>https://ndtinspect.com/groups/corrosion-mapping/forum/discussion/high-temperature-corrosion-mapping-utilizing-paut-method/</link>
				<pubDate>Mon, 18 Apr 2022 06:03:54 +0500</pubDate>

									<content:encoded><![CDATA[<p class = "activity-discussion-title-wrap"><a href="https://ndtinspect.com/groups/corrosion-mapping/forum/discussion/high-temperature-corrosion-mapping-utilizing-paut-method/">High temperature corrosion mapping utilizing PAUT method</a></p> <div class="bb-content-inr-wrap"><p>Have obtained high temperature corrosion mapping sets from Eclipse Scientific and they seem to be working great but we have only flat and not curved wedges for piping therefore cannot inspect anything below 20 inch. Does anybody know a company or supplier that produces high temperature wedges (custom type) that are capable of scanning up to&hellip;</p>
<p><span class="activity-read-more" id="activity-read-more-16259"><a href="https://ndtinspect.com/groups/corrosion-mapping/forum/discussion/high-temperature-corrosion-mapping-utilizing-paut-method/" rel="nofollow"> Read more</a></span></p>
</div>]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">78907b3b1ffcd5b368becbbf9bea793b</guid>
				<title>holld posted an update in the group Corrosion Mapping (CM): PAUT corrosion mapping with Hydrofom </title>
				<link>https://ndtinspect.com/news-feed/p/16220/</link>
				<pubDate>Tue, 12 Apr 2022 04:24:12 +0500</pubDate>

									<content:encoded><![CDATA[<p>PAUT corrosion mapping with Hydrofom </p>
]]></content:encoded>
				
									<slash:comments>0</slash:comments>
				
							</item>
					<item>
				<guid isPermaLink="false">94e98dbb59e3f8f67a6d61ec0a28a1d7</guid>
				<title>holld replied to the discussion AWS D1.1 Acceptance criteria in the forum Codes and Standards</title>
				<link>https://ndtinspect.com/groups/codes-and-standards/forum/discussion/aws-d11acceptance-criteria/#post-12413</link>
				<pubDate>Sun, 27 Mar 2022 04:13:26 +0500</pubDate>

									<content:encoded><![CDATA[<p class = "activity-discussion-title-wrap"><a href="https://ndtinspect.com/groups/codes-and-standards/forum/discussion/aws-d11acceptance-criteria/#post-12413"><span class="bb-reply-lable">Reply to</span> AWS D1.1 Acceptance criteria</a></p> <div class="bb-content-inr-wrap"><p>I have latest version of AWS Structural Steel 2020 standard but will not share it due to copyright. Instead, If anybody needs some info from standard, please contact me <a class='bp-suggestions-mention' href='https://ndtinspect.com/members/holld/' rel="nofollow">@Holld</a> and I will be happy to help.</p>
</div>]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">c3f73988203945660078191f893d7d36</guid>
				<title>holld replied to the discussion AWS D1.1 Acceptance criteria in the forum Codes and Standards</title>
				<link>https://ndtinspect.com/groups/codes-and-standards/forum/discussion/aws-d11acceptance-criteria/#post-12412</link>
				<pubDate>Sun, 27 Mar 2022 04:09:07 +0500</pubDate>

									<content:encoded><![CDATA[<p class = "activity-discussion-title-wrap"><a href="https://ndtinspect.com/groups/codes-and-standards/forum/discussion/aws-d11acceptance-criteria/#post-12412"><span class="bb-reply-lable">Reply to</span> AWS D1.1 Acceptance criteria</a></p> <div class="bb-content-inr-wrap"><p>Have also found AWS Ultrasonic procedure for AWS D1.1 Not sure if its any good but will share it anyway. For thicknesses 8-200mm Manual UT</p>
</div>]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">943617355a44e341fc9ece786780b5b4</guid>
				<title>holld replied to the discussion AWS D1.1 Acceptance criteria in the forum Codes and Standards</title>
				<link>https://ndtinspect.com/groups/codes-and-standards/forum/discussion/aws-d11acceptance-criteria/#post-12410</link>
				<pubDate>Sun, 27 Mar 2022 04:07:14 +0500</pubDate>

									<content:encoded><![CDATA[<p class = "activity-discussion-title-wrap"><a href="https://ndtinspect.com/groups/codes-and-standards/forum/discussion/aws-d11acceptance-criteria/#post-12410"><span class="bb-reply-lable">Reply to</span> AWS D1.1 Acceptance criteria</a></p> <div class="bb-content-inr-wrap"><p>Perfect. Thank you sir. Lets try to find as much info as possible regarding AWS D1.1 standard and acceptance criteria as search seem to be very limited.</p>
</div>]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">293e63733548775bc805648ab4501a45</guid>
				<title>holld replied to the discussion AWS D1.1 Acceptance criteria in the forum Codes and Standards</title>
				<link>https://ndtinspect.com/groups/codes-and-standards/forum/discussion/aws-d11acceptance-criteria/#post-12407</link>
				<pubDate>Sun, 27 Mar 2022 03:48:03 +0500</pubDate>

									<content:encoded><![CDATA[<p class = "activity-discussion-title-wrap"><a href="https://ndtinspect.com/groups/codes-and-standards/forum/discussion/aws-d11acceptance-criteria/#post-12407"><span class="bb-reply-lable">Reply to</span> AWS D1.1 Acceptance criteria</a></p> <div class="bb-content-inr-wrap"><p>Somebody might find this useful.</p>
<p>AWS-D1.1 Generalized Guidelines For Structural Steel Welding Inspection </p>
</div>]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">a3ac3331c5de9a235b35c380efeb2241</guid>
				<title>holld posted an update in the group Radiography: Acceptable?  &#x1f606;&#x1f606;&#x1f606;</title>
				<link>https://ndtinspect.com/news-feed/p/15898/</link>
				<pubDate>Thu, 17 Mar 2022 06:18:00 +0500</pubDate>

									<content:encoded><![CDATA[<p>Acceptable?  &#x1f606;&#x1f606;&#x1f606;</p>
]]></content:encoded>
				
									<slash:comments>0</slash:comments>
				
							</item>
					<item>
				<guid isPermaLink="false">ce5206deac0f4a72b8e7dbda2bcc991e</guid>
				<title>holld posted an update in the group Radiography: RT acceptance Criteria API, ANSI, ASME including ASME B31.3 </title>
				<link>https://ndtinspect.com/news-feed/p/15470/</link>
				<pubDate>Sat, 12 Feb 2022 11:40:55 +0500</pubDate>

									<content:encoded><![CDATA[<p><b>RT acceptance Criteria API, ANSI, ASME including ASME B31.3 </b></p>
<p><b><br /></b></p>
<p>RADIOGRAPHIC TESTING<br />
COMPARATIVE ACCEPTANCE CRITERIA pdf and word<b><br /></b></p>
<p>Asme-b31-3-Acceptance-Rt-Tabulated</p>
]]></content:encoded>
				
									<slash:comments>0</slash:comments>
				
							</item>
					<item>
				<guid isPermaLink="false">9fb46da360b2d409e44d8d4b7a3511f1</guid>
				<title>holld posted an update in the group Oil and Gas Sector: How They Built The World's Longest Underwater Pipeline [&#133;]</title>
				<link>https://ndtinspect.com/news-feed/p/15465/</link>
				<pubDate>Sat, 12 Feb 2022 09:45:14 +0500</pubDate>

									<content:encoded><![CDATA[<p><b>How They Built The World&#8217;s Longest Underwater Pipeline | Megastructures | Spark </b></p>
<p>By two thousand and eight, Norway will be connected to the United Kingdom via a 1200 km super pipeline—the longest subsea pipeline in the world. </p>
<p> But this connection is only a part of an enormous plan to tap into Norway’s second largest gas deposit, capable of&hellip;</p>
<p><span class="activity-read-more" id="activity-read-more-15465"><a href="https://ndtinspect.com/news-feed/p/15465/" rel="nofollow"> Read more</a></span></p>
]]></content:encoded>
				
									<slash:comments>0</slash:comments>
				
							</item>
					<item>
				<guid isPermaLink="false">43cbec3af5c3caf2b291a0d0d3038eac</guid>
				<title>Holld posted an update</title>
				<link>https://ndtinspect.com/news-feed/p/15360/</link>
				<pubDate>Mon, 07 Feb 2022 15:23:24 +0500</pubDate>

									<content:encoded><![CDATA[<p>Defect on a nozzle from inside is:</p>
]]></content:encoded>
				
									<slash:comments>0</slash:comments>
				
							</item>
					<item>
				<guid isPermaLink="false">1f31ee4ee45686557c37a0225b0c49fc</guid>
				<title>holld started the discussion Diamond Wrap thickness testing and NDT in the forum Coating Inspection</title>
				<link>https://ndtinspect.com/groups/coating-inspection/forum/discussion/diamond-wrap-thickness-testing-and-ndt/</link>
				<pubDate>Fri, 21 Jan 2022 01:36:52 +0500</pubDate>

									<content:encoded><![CDATA[<p class = "activity-discussion-title-wrap"><a href="https://ndtinspect.com/groups/coating-inspection/forum/discussion/diamond-wrap-thickness-testing-and-ndt/">Diamond Wrap thickness testing and NDT</a></p> <div class="bb-content-inr-wrap"><p>What is the best method to perform thickness inspection on diamond wrap? We have a client that has requested thickness testing on a diamond wrap placed on piping with operating temperature of 120 degrees C and diamond wrap thickness = 1.5mm or less. One of the options is use of small diameter, low frequency transducer (like aircraft&hellip;</p>
<p><span class="activity-read-more" id="activity-read-more-14154"><a href="https://ndtinspect.com/groups/coating-inspection/forum/discussion/diamond-wrap-thickness-testing-and-ndt/" rel="nofollow"> Read more</a></span></p>
</div>]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">98ef9f527379dedc9a2680cf58fb4537</guid>
				<title>holld posted an update in the group Aerospace Sector: NDT, UT and inspection of composite materials</title>
				<link>https://ndtinspect.com/news-feed/p/14150/</link>
				<pubDate>Thu, 20 Jan 2022 04:59:44 +0500</pubDate>

									<content:encoded><![CDATA[<p>NDT, UT and inspection of composite materials</p>
]]></content:encoded>
				
									<slash:comments>0</slash:comments>
				
							</item>
					<item>
				<guid isPermaLink="false">9559479e72500b1482aef6af448e83dd</guid>
				<title>holld posted a new activity comment</title>
				<link>https://ndtinspect.com/news-feed/p/12637/#acomment-12641</link>
				<pubDate>Mon, 27 Dec 2021 18:08:25 +0500</pubDate>

									<content:encoded><![CDATA[<p>Welcome&nbsp;&#x1f44b;</p>
				<strong>In reply to</strong> -
					<a href="https://ndtinspect.com/members/kitry/" data-bb-hp-profile="914" rel="nofollow">kitry</a> posted an update <p>Hi @all &#x1f642;</p>					]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">f71e5f28c202d0ff5c05d42fd5ec8e7d</guid>
				<title>holld posted an update: Radiography Testing Film Interpretation&#124; NDT &#124; [&#133;]</title>
				<link>https://ndtinspect.com/news-feed/p/12491/</link>
				<pubDate>Tue, 14 Dec 2021 12:44:44 +0500</pubDate>

									<content:encoded><![CDATA[<p></p>
<p>Radiography Testing Film Interpretation| NDT | welding Defects | ASNT</p>
<p><a target='_blank' href="https://www.youtube.com/watch?v=1IIhSGgSD3A" rel="nofollow">https://www.youtube.com/watch?v=1IIhSGgSD3A</a> </p>
<p><iframe class="lazy" title="Radiography  Testing Film Interpretation|NDT|welding Defects|ASNT" width="640" height="360"  data-lazy-type="iframe" data-src="https://www.youtube.com/embed/1IIhSGgSD3A?feature=oembed" frameborder="0" allow="accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share" referrerpolicy="strict-origin-when-cross-origin" allowfullscreen></iframe></p>
]]></content:encoded>
				
									<slash:comments>0</slash:comments>
				
							</item>
					<item>
				<guid isPermaLink="false">f9b8bd5b1bd794db0ed972004085db00</guid>
				<title>holld and andts are now connected</title>
				<link>https://ndtinspect.com/news-feed/p/12490/</link>
				<pubDate>Tue, 14 Dec 2021 12:41:19 +0500</pubDate>

				
									<slash:comments>0</slash:comments>
				
							</item>
					<item>
				<guid isPermaLink="false">96f4c347a1c37f0215391d888ba150cc</guid>
				<title>holld started the discussion AWS D1.1 Acceptance criteria in the forum Codes and Standards</title>
				<link>https://ndtinspect.com/groups/codes-and-standards/forum/discussion/aws-d11acceptance-criteria/</link>
				<pubDate>Tue, 14 Dec 2021 02:11:38 +0500</pubDate>

									<content:encoded><![CDATA[<p class = "activity-discussion-title-wrap"><a href="https://ndtinspect.com/groups/codes-and-standards/forum/discussion/aws-d11acceptance-criteria/">AWS D1.1 Acceptance criteria</a></p> <div class="bb-content-inr-wrap"><p>#UT #AWS #question </p>
<p>I,m looking for some old school Ut specialist that can answer me some questions. </p>
<p> I,m currently starting a project which gone use AWS D1.1 acceptance criteria, to be exact table 6.3 (cyclically loaded nontubular connections in tension) and im lost. </p>
<p>I can easily count indication rating (6.25.6.5), which, when larger&hellip;</p>
<p><span class="activity-read-more" id="activity-read-more-12486"><a href="https://ndtinspect.com/groups/codes-and-standards/forum/discussion/aws-d11acceptance-criteria/" rel="nofollow"> Read more</a></span></p>
</div>]]></content:encoded>
				
				
							</item>
					<item>
				<guid isPermaLink="false">af64b4a6f98fdf0d3be70feb9b5824fc</guid>
				<title>holld posted an update: Winter...</title>
				<link>https://ndtinspect.com/news-feed/p/12474/</link>
				<pubDate>Mon, 13 Dec 2021 09:43:51 +0500</pubDate>

									<content:encoded><![CDATA[<p>Winter&#8230;</p>
]]></content:encoded>
				
									<slash:comments>0</slash:comments>
				
							</item>
		
	</channel>
</rss>
		