PAUT inspection on a 6mm Carbon Steel line. Cracking detection on a painted surface. Looking for Caustic cracking (Caustic Embrittlement) . Which probe to use? 🤔
NDT-Inspect and holld-
-
Well, MPI has confirmed PAUT findings after the line has been removed out of service. It looks beautiful? 😝
-
-
Stress Corrosion Cracking Issues inSyngas Plants that may be Missed by Risk-Based Assessment (interesting read)
-