Personnel dose tracker

Occupational dose limits for radiation workers follow ICRP Publication 103 and are given effect in IAEA GSR Part 3 and in national regulations. The effective dose limit is 20 mSv per year averaged over five consecutive years, that is 100 mSv in any five-year period, with the further condition that no single year may exceed 50 mSv. The averaging exists so that an unusual outage year does not by itself breach the limit, but the five-year total is a hard cap and the single-year ceiling stops the whole allowance being spent at once.

Limits are not targets. The optimisation principle requires dose to be kept as low as reasonably achievable below them, and employers implement that through a dose constraint – a self-imposed ceiling, commonly 6 mSv per year for industrial radiographers, that triggers investigation long before any legal limit is approached. In practice a well-run gamma crew records 1 to 3 mSv a year, so a constraint being approached is a signal that something in the working method has changed.

Projecting the year-end dose from the year to date is the routine control. Scaling the accumulated dose by the fraction of the year elapsed gives an early warning while there is still time to redistribute work, review techniques or increase barrier distances. The same arithmetic on the five-year running total shows whether an individual is on course to hit the 100 mSv cap.

Separate limits apply to the lens of the eye (20 mSv per year) and to skin and extremities (500 mSv per year), and different, much lower limits apply to members of the public and to declared pregnant workers. Those are not covered here – refer them to the radiation protection adviser.

Worked example

Dose this year to date4.2 mSv
Months elapsed this year5
Cumulative dose in the five-year period31 mSv
Years elapsed in the five-year period2.5 y
Employer dose constraint6 mSv
Annual average limit20 mSv
Five-year total limit100 mSv
Projected dose this year10.08 mSv
Remaining to the annual average limit15.8 mSv
Remaining in the five-year period69 mSv
Percent of annual limit used21 %
Percent of employer constraint used70 %
Five-year average to date12.4 mSv
Remaining monthly budget to stay under 20 mSv2.26 mSv

4.2 mSv in 5 months projects to 4.2 x 12/5 = 10.08 mSv for the year - above the 6 mSv constraint but below the 20 mSv limit. 15.80 mSv of the annual allowance and 69.00 mSv of the five-year allowance remain. The five-year average so far is 31.0/2.5 = 12.40 mSv per year. Spreading the remaining 15.80 mSv over the remaining 7 months gives 2.26 mSv per month.

Use at your own risk — verify before you act

These calculators support, and never replace, the judgement of qualified NDT and engineering personnel. Results are provided as is, without warranty of any kind, express or implied, and must be independently verified against the governing code edition named in your contract before being used in any inspection, acceptance, rejection, radiation-safety or fitness-for-service decision. By using them you accept full responsibility for how the results are applied; NDT Inspect, its owners and contributors accept no liability for any loss, damage, injury or death arising from their use or from reliance on them. If a result matters to safety, check it by hand and have it reviewed by a competent person.

Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.