ToFD backwall dead zone

Resolution near the far surface is limited in the same way as near the scanning surface, but by the backwall reflection instead of the lateral wave. A tip close to the backwall diffracts a signal that arrives only slightly before the backwall echo, and if that gap is shorter than the pulse duration the two cannot be separated.

Setting the time difference equal to the pulse duration gives the deepest resolvable tip: d_max = sqrt((sqrt(S^2 + T^2) - c*tau/2)^2 - S^2). The dead zone is what remains of the wall, T – d_max. It is normally much thinner than the near-surface dead zone because the arrival-time curve is steep at that depth, but it is real, and mode-converted signals that follow the backwall make it worse in practice than the geometry alone suggests.

Root defects therefore need a complementary technique. In practice the backwall itself carries most of the useful information: a root-breaking flaw locally removes, delays or phase-reverses the backwall, and that behaviour is usually more reliable than searching for a separate tip signal a fraction of a microsecond ahead of it.

In practice the probe angle is chosen first and the PCS follows from it: with the beams crossed at two-thirds of the wall, PCS = (4/3)·T·tan θ. A 70° setup therefore carries a much wider PCS than a 45° one on the same wall, and since the dead zone grows with the probe separation, the chosen angle directly changes the dead zone. This calculator accepts either the angle (and derives the PCS) or a PCS you have already fixed.

Compression wave

Worked example

How to set the PCSderive
Refracted beam angle60 deg
Wall thickness25 mm
Probe centre separation70 mm
Probe centre frequency5 MHz
Cycles in the pulse2
Compression velocity5900 m/s
PCS in use57.7 mm
Half separation28.87 mm
Pulse duration0.4 µs
Half backwall path38.19 mm
Deepest resolvable tip23.16 mm
Backwall dead zone height1.84 mm

60° on 25 mm wall: PCS = 57.74 mm, S = 28.87 mm. R = √(28.87² + 25²) = 38.19 mm. Half pulse = 1.18 mm. d_max = √((38.19 − 1.18)² − 28.87²) = 23.16 mm, so the last 1.84 mm above the backwall cannot be resolved.

Use at your own risk — verify before you act

These calculators support, and never replace, the judgement of qualified NDT and engineering personnel. Results are provided as is, without warranty of any kind, express or implied, and must be independently verified against the governing code edition named in your contract before being used in any inspection, acceptance, rejection, radiation-safety or fitness-for-service decision. By using them you accept full responsibility for how the results are applied; NDT Inspect, its owners and contributors accept no liability for any loss, damage, injury or death arising from their use or from reliance on them. If a result matters to safety, check it by hand and have it reviewed by a competent person.

Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.