Phased Array Ultrasonics (PAUT)
Welcome to [NDT Inspection Portal]’s phased array ultrasonics (PAUT) group, a place for professionals... View more
Group Feed
kevlin posted an update in the group Phased Array Ultrasonics (PAUT) 2 years ago
Omniscan MX, MX1, and MX2 User’s Manual
https://www.olympus-ims.com/en/downloads/detail/?0%5Bdownloads%5D%5Bid%5D=276829662
vincent-wu posted an update in the group Phased Array Ultrasonics (PAUT) 2 years ago
NDT-Inspect posted an update in the group Phased Array Ultrasonics (PAUT) 2 years ago
2 years ago (edited)
NDT-Inspect started the discussion Weld Setup Instructions for the MX2 in the forum Phased Array 2 years ago
Weld Setup Instructions for the MX2
Setup Instructions for the MX2
Firstly connect the probe to the OmniScan. If making a double sided setup connect probes to splitter and then connect splitter to the OmniScan.
FILE > NEW
WIZARD > PART+WELD (Follow through wizard)
Enter THICKNESS
WELD TYPE = V OFFSET
Enter weld configuration
FINISH
WIZARD > SETUP (Follow…
andts posted an update in the group Phased Array Ultrasonics (PAUT) 2 years ago
Detection, characterization and sizing of hydrogen induced cracking in pressure vessels using phased array ultrasonic data processing
chris posted an update in the group Phased Array Ultrasonics (PAUT) 2 years ago
2 years ago (edited)
PAUT inspection on a 6mm Carbon Steel line. Cracking detection on a painted surface. Looking for Caustic cracking (Caustic Embrittlement) . Which probe to use? 🤔
NDT-Inspect and holld4 CommentsStress Corrosion Cracking Issues inSyngas Plants that may be Missed by Risk-Based Assessment (interesting read)
NDT-Inspect posted an update in the group Phased Array Ultrasonics (PAUT) 2 years ago
Heavy wall Nozzle inspection for cracking
andts posted an update in the group Phased Array Ultrasonics (PAUT) 2 years ago
mohamed-ali-bagath joined the group Phased Array Ultrasonics (PAUT) 2 years ago
ketkon started the discussion PAUT Focusing problems (Near Field Length Compensation Options) in the forum Phased Array 2 years ago
PAUT Focusing problems (Near Field Length Compensation Options)
Abstract
In a previous report by the authors, the relative accuracy of Beamtool as it relates to calculations of several beam parameters was considered. Comparison of the values obtained by Beamtool, to those obtained from Civa, indicated that the traditional approximations used in Beamtool were reasonably close to what might be predicted…
ramakrishnan-n96gmail-com and NDT-InspectNDT-Inspect started the discussion The Future of Phased Array Ultrasonic Testing: FMC / TFM in the forum Phased Array 2 years ago
The Future of Phased Array Ultrasonic Testing: FMC / TFM
Posted by Vrana GmbH
The Total Focusing Method (TFM) is an important step toward the future of Phased Array Ultrasonic Testing as it eliminates most of the artifacts caused by sector scans or linear scans. It uses standard phased array probes – but instead of using delay laws it uses Full Matrix Capture (FMC) to collect the data and the…
harry started the discussion Phased array instruments and ability to define anisotropic velocity? in the forum Phased Array 3 years ago
Phased array instruments and ability to define anisotropic velocity?
Does anyone know of any PAUT equipment that allows you to define velocity as a function of angle? I believe that Olympus PipeWIZARD V4 has this capability, but beyond that I’m not aware of any regular sort of, “field portable” PAUT set that permits you define velocity as a function of angle (a “velocity vector”, if you will).
Last year I… Read more
NDT-Inspect started the discussion What is Phased Array Ultrasonics PAUT? in the forum Phased Array 3 years ago
What is Phased Array Ultrasonics PAUT?
The focus of the ultrasonic beam is on a time delay between several piezoelectric crystals which can transmit and receive independently at different times, creating a constructive interference wavefront that allows energy to focus on the depth at which the sample is examined. The Calculator determines the delay time between the fire group… Read more
marat posted an update in the group Phased Array Ultrasonics (PAUT) 3 years ago
3 years ago (edited)
PAUT vs RT
A comparison with RT in this particular application produced the overview presented in the Table below.
In conclusion:
• PA dramatically reduces health & safety implications;
• PA offers advantages in saving time and money;
• The advantages and limitations of each technique have been presented;
• Radiography offers benefits for the…