ToFD depth zone division
A single ToFD setup covers a limited depth range. Diffracted amplitude falls away from the beam crossing point, and the near-surface and backwall dead zones consume both ends of the wall. Above roughly 50 mm of thickness one setup can no longer be shown to cover everything, so the examination is split into depth zones, each with its own probe pair, angle, frequency and probe centre separation, and the resulting images are stacked to cover the full wall.
Within each zone the same two-thirds rule is applied: the beam axes are made to cross two-thirds of the way through the zone, measured from the top of that zone. The PCS then follows from the zone boundaries and the beam angle. For a single zone spanning the whole wall this reduces exactly to the familiar PCS = (4/3)*T*tan(theta). Some procedures instead place the crossing point at the centre of each zone; the fraction is selectable here and the governing procedure decides which applies. Deeper zones use lower frequency, larger elements and shallower angles to keep the sound path and the attenuation under control.
The arrival-time window of a zone is bounded by the times from its upper and lower boundary depths, computed with that zone PCS. For the first zone the upper boundary is the scanning surface, so the window starts at the lateral wave. Those two times are what the gate is set from for that setup.
Adjacent zones must overlap, and the coverage of every zone has to be demonstrated on a reference block with targets at the zone boundaries. The calculation fixes geometry only; it does not prove sensitivity, and the boundary regions are exactly where sensitivity is weakest.
Compression wave
Worked example
| Wall thickness | 90 mm |
| Number of zones | 2 |
| Zone number | 2 |
| Refracted beam angle for this zone | 45 deg |
| Compression velocity | 5900 m/s |
| Crossing point within the zone | twothirds |
| Recommended number of zones | 2 |
| Zone depth range | 45 mm |
| Zone upper boundary | 45 mm |
| Zone lower boundary | 90 mm |
| Beam crossing depth | 75 mm |
| Half separation | 75 mm |
| PCS for this zone | 150 mm |
| Arrival time at zone top | 29.65 µs |
| Arrival time at zone bottom | 39.71 µs |
A 90 mm wall falls in the band needing two setups. Each zone is 90/2 = 45 mm deep, so zone 2 runs from 45 mm to 90 mm. The crossing point is two-thirds through the zone, 45 + 30 = 75 mm. tan(45 deg) = 1, so S = 75 mm and PCS = 150 mm. With c = 5.9 mm/us, the zone top gives 2 x sqrt(75^2 + 45^2)/5.9 = 2 x sqrt(7650)/5.9 = 2 x 87.4643/5.9 = 29.6489 us, that is 29.65 us; the zone bottom gives 2 x sqrt(75^2 + 90^2)/5.9 = 2 x sqrt(13725)/5.9 = 2 x 117.1537/5.9 = 39.7131 us, that is 39.71 us.
Use at your own risk — verify before you act
These calculators support, and never replace, the judgement of qualified NDT and engineering personnel. Results are provided as is, without warranty of any kind, express or implied, and must be independently verified against the governing code edition named in your contract before being used in any inspection, acceptance, rejection, radiation-safety or fitness-for-service decision. By using them you accept full responsibility for how the results are applied; NDT Inspect, its owners and contributors accept no liability for any loss, damage, injury or death arising from their use or from reliance on them. If a result matters to safety, check it by hand and have it reviewed by a competent person.