ToFD PCS from the two-thirds wall rule

Wave mode: compression

The conventional single-setup ToFD arrangement places the intersection of the two beam axes at two-thirds of the wall thickness. Substituting d = 2T/3 into PCS = 2*d*tan(theta) gives PCS = (4/3)*T*tan(theta).

The two-thirds rule is a deliberate compromise. Diffracted energy falls away from the beam axis, and the geometry already favours shallow flaws because their paths are shorter and less attenuated. Aiming the crossing point below mid-wall pushes sensitivity down toward the lower third, where the sound path is longest, while still leaving enough energy in the upper wall for the lateral wave and near-surface region to remain usable.

The rule applies to a single setup covering the full wall. Above roughly 50 mm of thickness the examination is split into depth zones with separate probe pairs, and the two-thirds rule is then applied within each zone rather than to the whole thickness.

The lateral wave and backwall times that follow from the resulting geometry are the numbers to check on the instrument. If they do not appear where predicted, the PCS, the thickness or the velocity is wrong, and no depth taken from that setup can be trusted.

d_cross = (2/3) × T
PCS = 2 × d_cross × tan(θ) = (4/3) × T × tan(θ)
t_LW = PCS / c
t_BW = 2 × √(S² + T²) / c

Members-only calculator

Sign in or join free to use the full NDT toolbox.

Sign in View memberships

Notes:
  • Single-setup rule only. Above about 50 mm of wall the examination is normally split into depth zones.
  • The lateral wave and backwall times shown exclude probe delay; add the measured wedge delay before setting cursors.
  • The two-thirds rule fixes geometry only. Sensitivity across the full wall still has to be demonstrated on a reference block.

Reference: ISO 10863:2011 §7 (two-thirds wall thickness beam intersection); ASTM E2373/E2373M; ASME BPVC Section V, Article 4, Mandatory Appendix III

These calculators support — never replace — calculations against the governing code edition and your written procedure. Verify results independently before use.

Related calculators

193 calculations with worked examples

NDT calculators

All calculators

955 discussions · 382 answers

Latest forum discussions

Open the forum
Process columns and pipe racks against a blue sky

Looking for work?

105 live NDT vacancies worldwide

Upload your CV once and get new vacancies for your methods by email.

Sponsors of NDT Inspect
Magnaflux
Sponsor slot open