Radiographic Testing (RT): Questions Answered

4 chapters 11 sections 16 min read

November 25, 2026 · by NDT Inspect (admin)

Radiographic Testing (RT): Questions Answered
Chapter 1 of 4

Setting up the shot: distances and unsharpness

2 sections · 4 min read

How do I calculate source-to-object distance (SOD) and source-to-film distance (SFD)?

Source-to-film distance is the source-to-object distance plus the object-to-film distance: SFD = SOD + t. The shortest SOD you may use comes from the unsharpness limit: SODmin = F × t / Ugmax.

SFD is what you tape on site, from the source (pellet centre or focal spot) to the film. SOD runs to the source side of the object, such as the top of the weld cap, and t is everything from there to the film: material, cap, cassette and any gap.

SFD = SOD + t

SODmin = F × t / Ugmax

F = source size (mm), from the gamma source certificate or the tube's effective focal spot (ASTM E1165 covers pinhole measurement); Ugmax = the limit your code or procedure uses (mm).

Worked example. Butt weld in 19 mm plate, 2 mm cap on the source side, film in contact, Ir-192 source 2.0 mm, ASME Section V recommended limit 0.51 mm.

  1. t = 19 + 2 = 21 mm.
  2. SODmin = 2.0 × 21 / 0.51 = 82 mm.
  3. SFDmin = 82 + 21 = 103 mm.
  4. Set up at SFD 500 mm instead: SOD = 479 mm and Ug = 2.0 × 21 / 479 = 0.09 mm.

The minimum is rarely the distance you use, because on thin welds coverage sets the SFD. ISO 17636-1 limits the penetrated thickness at the edge of the evaluated area to 1.1 times the centre value in class B (1.2 in class A). On a flat plate in class B, that keeps the length evaluated per exposure a little under the SOD: 400 mm of weld needs an SOD of about 440 mm.

On pipe, t depends on the technique. It is the wall plus cap for panoramic, single-wall and double-wall single-image shots (some procedures conservatively use the outside diameter for the last). For double-wall double-image (elliptical) shots it is about the full outside diameter, which is why they need a long SFD.

Try it: Minimum SOD · Minimum SOD for pipe · Elliptical double-wall technique

What is geometric unsharpness in radiography, and what is the limit?

Geometric unsharpness (Ug) is the blurred edge, or penumbra, that every feature casts because the source has a finite size, calculated as Ug = F × t / D. ASME Section V recommends a maximum of 0.51 mm (0.020 in) for material under 50 mm thick, rising in steps to 1.78 mm (0.070 in) over 100 mm.

Ug = F × t / D

F = source size (mm); t = distance from the source side of the object to the film (mm); D = source-to-object distance (mm). From a measured SFD: Ug = F × t / (SFD − t).

Geometric unsharpness in radiographyA source of size F sits a distance D above the object. The object-to-film distance is t, and SFD is D plus t. Rays from the two edges of the source pass the same edge of a feature on the source side of the object and reach the film a short distance apart. That band on the film is the geometric unsharpness, Ug, equal to F times t divided by D.FSourceD (SOD)tSFDObjectFeatureFilmUgUg = F × t / DSFD = D + t

Rays from the two edges of the source pass the same feature edge and land Ug apart on the film. More distance (D) or a smaller gap (t) shrinks Ug. Not to scale.

ASME Section V, Article 2 recommends these maximum values, by the thickness on which the IQI is based:

Material thicknessRecommended maximum Ug
Under 50 mm (2 in)0.51 mm (0.020 in)
50 to 75 mm (2 to 3 in)0.76 mm (0.030 in)
Over 75 to 100 mm (3 to 4 in)1.02 mm (0.040 in)
Over 100 mm (4 in)1.78 mm (0.070 in)

Older editions made these limits mandatory and current ones call them recommended, but a referencing code, procedure or client specification can still make them binding.

ISO 17636-1 instead sets a minimum source-to-object distance f from the source size d and the object-to-film distance b, all in mm. The letters differ from ASME.

Class A: f / d ≥ 7.5 × b2/3

Class B: f / d ≥ 15 × b2/3

Worked example. 25 mm plate, weld ground flush, film in contact (t = b = 25 mm), Ir-192 source 3.0 mm.

  1. ASME: Dmin = 3.0 × 25 / 0.51 = 147 mm.
  2. ISO class A: 252/3 = 8.55, so fmin = 7.5 × 8.55 × 3.0 = 192 mm.
  3. ISO class B: fmin = 15 × 8.55 × 3.0 = 385 mm, which corresponds to Ug = 3.0 × 25 / 385 = 0.19 mm.

ISO class B is the tighter rule here. Film grain or detector pixels add further unsharpness, which often dominates on digital systems.

Try it: Geometric unsharpness calculator

Next chapterImage quality: IQIs, sensitivity, density and reshoots
Chapter 2 of 4

Image quality: IQIs, sensitivity, density and reshoots

4 sections · 6 min read

How do I choose the IQI, and which wire or hole must be visible?

Pick the IQI from your code's selection table by material thickness, and place it on the source side unless you cannot reach it. The radiograph is fit to interpret only if the essential wire, or the designated hole (usually 2T) of the specified hole-type IQI, is visible.

ASME Section V, Article 2 accepts hole-type IQIs to SE-1025 and wire IQIs to SE-747. Enter its selection table, T-276, with the nominal single-wall thickness plus the estimated weld reinforcement the referencing code allows; backing rings and strips are not counted. It gives a hole-type IQI with its essential hole, and an essential wire, for each side.

  • The film side is used only where the source side cannot be reached. Mark the IQI with a lead letter F and use the film-side column, which calls for a smaller IQI because an IQI next to the film images more sharply.
  • Hole-type IQIs go on or beside the weld (on a shim where needed) with their numbers outside the area of interest; wire IQIs go on the weld with the wires across it.
  • The hole-type designation is the plaque thickness in thousandths of an inch: number 20 is 0.020 in (0.51 mm) thick, with holes of 1T, 2T and 4T diameter.

"2-2T" is a quality level: a plaque 2% of the part thickness with the 2T hole visible, equal to 2% equivalent sensitivity. Your code or specification names the level that applies.

ISO 17636-1 uses wire IQIs to ISO 19232-1 (or step/hole IQIs to ISO 19232-2) in sets of seven wires: W1 to W7, W6 to W12, W10 to W16 and W13 to W19, from 3.20 mm down to 0.050 mm. Annex B gives the required wire by class, technique and IQI position: single-wall shots by nominal thickness, double-wall shots by penetrated thickness (both walls), with separate tables for a detector-side IQI. A wire counts as visible when at least 10 mm of it shows continuously in an area of even density.

The IQI proves the technique, not the weld. ISO 17636-1 film-side selection is debated in the forum thread on IQI selection.

Try it: IQI selection calculator

How do I calculate radiographic sensitivity?

Radiographic sensitivity is the smallest visible IQI feature as a percentage of the penetrated thickness: sensitivity (%) = smallest visible wire diameter / thickness × 100. Lower is better, and 2% is the common benchmark.

S (%) = d / T × 100

d = diameter of the thinnest visible wire (mm); T = penetrated thickness, including the cap if your code counts it (mm).

For a hole-type IQI with the 2T hole visible, sensitivity is simply plaque thickness divided by part thickness. To compare 1T, 2T and 4T readings, ASTM E1025 defines the equivalent penetrameter sensitivity:

EPS (%) = (100 / X) × √(T × H / 2)

X = part thickness; T = plaque thickness; H = diameter of the smallest visible hole, all in the same unit.

Worked example.

  1. Wire IQI on a 20 mm weld, thinnest visible wire W12 (0.25 mm): S = 0.25 / 20 × 100 = 1.25%.
  2. Hole IQI number 20 (0.51 mm) on 25.4 mm (1 in) steel, 2T hole visible: EPS = 0.51 / 25.4 × 100 = 2.0%.
  3. Same IQI, only the 4T hole (2.03 mm) visible: EPS = (100 / 25.4) × √(0.51 × 2.03 / 2) = 2.8%.

Two cautions. Codes rarely accept a radiograph on a percentage; they name a wire or hole, and the percentage goes on the report or is used to compare techniques. And wire and hole percentages are not interchangeable, because a wire and a hole of the same size are not equally easy to see. If a specification asks for "2% sensitivity", ask which IQI and which wire or hole it means.

More cases are in the forum thread on sensitivity calculation; practise in the calculation drills.

Try it: Radiographic sensitivity calculator

What film density is acceptable in radiography, and how much may it vary?

Under ASME Section V, density through the IQI and the area of interest must be at least 1.8 for single-film X-ray radiographs and 2.0 for gamma, with a maximum of 4.0, and the area of interest may differ from the IQI density by no more than −15% or +30%. ISO 17636-1 sets minimum densities of 2.0 for class A and 2.3 for class B.

Density is read with a calibrated densitometer through the body of the hole-type IQI next to the designated hole (or beside the essential wire) and across the area of interest. The ASME Article 2 rules:

  • Single-film viewing: minimum 1.8 for X-ray, 2.0 for gamma; maximum 4.0.
  • Composite viewing of two films: each film at least 1.3, the pair no more than 4.0.
  • A tolerance of 0.05 is allowed between densitometer readings.
  • If any part of the area of interest is more than 15% lighter or 30% darker than at the IQI, add an IQI for that area and reshoot. Limits may be rounded to the nearest 0.1. With a shim under a hole-type IQI, the +30% limit may be exceeded if the required IQI sensitivity is still met.

Worked example. Gamma shot, density beside the 2T hole 2.6.

  1. Lower limit: 2.6 × 0.85 = 2.21, rounded to 2.2.
  2. Upper limit: 2.6 × 1.30 = 3.38, rounded to 3.4.
  3. Both are inside 2.0 to 4.0, so the whole area of interest must read 2.2 to 3.4.
  4. A reading of 3.6 at the film end fails, even though it is under 4.0: add an IQI there and reshoot.

ISO 17636-1 has no fixed maximum in the ASME sense; the highest usable density depends on how bright the viewer is, which ISO 5580 covers. Higher density gives more contrast, so many radiographers aim for about 2.5 to 3.5.

Try it: Film density adjustment calculator

What are artefacts on a radiograph, and when must I reshoot?

Artefacts (artifacts in US spelling) are marks that do not come from the object: pressure and crimp marks, static, screen marks, chemical stains and light leaks. Reshoot when one sits in the area of interest and could hide or be mistaken for a discontinuity, or when density, the IQI, identification or coverage fails.

ArtefactLooks likeUsual cause
Pressure marksDark or light patchesClamps, tight cassettes, stacking, handling
Crimp marksShort crescents, light or darkFilm bent sharply, before or after exposure
StaticDark branched or spotty marksFast film handling in dry air
Screen marksMarks repeating on every film from one cassetteScratched, dented or dirty lead screens
Chemical stainsStreaks, drying marks, yellow or brown stainsPoor agitation, splashes, exhausted fixer, poor washing
Light leaks and fogDark areas with sharp edges; overall greyingDamaged cassettes, darkroom leaks, old film, scatter

Digital images have their own: plate scratches, ghosts from incomplete erasure, and bad detector pixels.

ASME Section V requires radiographs to be free of blemishes such as fog, processing marks, scratches, crimps, static and false indications from defective screens, to the extent that they could mask or be confused with a discontinuity in the area of interest. Reshoot when:

  • density is outside the limits or the variation range;
  • the essential wire or designated hole, or the IQI number, cannot be seen;
  • location markers, identification or overlap are missing or wrong;
  • the lead letter B on the back of the cassette shows light on a darker background, meaning too much backscatter (a dark B is no reason to reject);
  • an artefact masks or mimics an indication in the area of interest.

In doubt, reshoot with another cassette: artefacts move with the film or screen, real indications stay with the weld. What is then accepted belongs to the weld acceptance criteria. Practise reading with radiography film interpretation, weld metal RT film interpretation and the RT film reading simulator.

Next chapterExposure time and radiation safety
Chapter 3 of 4

Exposure time and radiation safety

2 sections · 3 min read

How do I calculate exposure time for Ir-192, Se-75 or X-ray?

For gamma rays, exposure = activity × time, so time = required exposure ÷ today's activity, with the exposure read from your chart for the thickness, film and SFD. Correct for distance with the inverse square law and for decay with the half-life: Ir-192 about 74 days, Se-75 about 120 days, Co-60 about 5.27 years.

An exposure chart is drawn for one material, film class, screen set, density and SFD. It gives the exposure each thickness needs: Ci·min or GBq·min for gamma, mA·min at a set kV for X-ray.

t = E / A

E2 = E1 × (SFD2 / SFD1)²

A = A0 × 0.5(days / T½)

t = time (min); E = exposure (Ci·min or GBq·min); A = activity today; A0 = activity on the source certificate; days = days since the certificate date; T½ = half-life (73.8 days for Ir-192, 119.8 for Se-75, about 1,925 for Co-60).

  • Film: finer grain needs more exposure; take the ratio from the maker's data.
  • Density: exposure and density are not proportional, so correct a light or dark shot with the film's characteristic curve.
  • X-ray: at the same kV, mA·min follows the distance rule; a kV change needs the chart.

Worked example. Two weeks ago a 60 Ci (2.22 TBq) Ir-192 source at SFD 500 mm gave density 2.6 in 2.0 minutes. Today you need SFD 700 mm on the same weld, film and processing.

  1. Exposure used: 60 × 2.0 = 120 Ci·min at 500 mm.
  2. New distance: 120 × (700 / 500)² = 120 × 1.96 = 235 Ci·min.
  3. Decay over 14 days: A = 60 × 0.5(14 / 73.8) = 60 × 0.877 = 52.6 Ci.
  4. Time: 235 / 52.6 = 4.47 min, about 4 minutes 28 seconds.

Ir-192 loses close to 1% of its activity a day, so recalculate every shift. Se-75 gives better contrast on thin steel, Co-60 suits thick sections, and ISO 17636-1 limits the thickness range for each source by class. Thick sections are discussed in the forum thread on exposure time.

Try it: Exposure time · Exposure transfer to a new distance · Source decay · RT exposure simulator

How far is a safe distance from a radiography source?

There is no single safe distance: it is where the dose rate falls to the boundary value your national regulations set, worked out from dose rate = Γ × A / d² and confirmed with a survey meter. For an unshielded 50 Ci Ir-192 source it can exceed 100 m, which is why collimators and shielding are normal practice.

Ḋ = Γ × A / d²

d = √(Γ × A / Ḋlimit)

Ḋ = dose rate; Γ = gamma constant (Ir-192 about 0.48 R·m²/h per Ci; Co-60 about 1.3); A = activity (Ci); d = distance (m). Roentgen-to-sievert conversions range from about 8.8 to 10 mSv per R depending on the dose quantity; the example uses the cautious 10.

Worked example. Bare 50 Ci (1.85 TBq) Ir-192 source in the open; the 7.5 µSv/h boundary is only an example.

  1. Dose rate at 1 m: 0.48 × 50 = 24 R/h, about 240 mSv/h (240,000 µSv/h).
  2. Boundary: d = √(240,000 / 7.5) = √32,000 = 179 m.
  3. With a collimator that cuts the rate outside the beam to 1/100 (check its data sheet): d = √(2,400 / 7.5) = 18 m. In the beam itself, only the object and shielding reduce it.

Each half-value layer (HVL) halves the dose rate; about 3.3 HVL cut it to a tenth. For Ir-192 one HVL is roughly 4.8 mm of lead, 12.7 mm of steel or 45 mm of concrete; for Co-60, roughly 12.5 mm, 22 mm and 62 mm. Published figures vary with the data source.

Boundary values are national and differ. Some regimes use a few µSv/h for a controlled area; US rules limit unrestricted areas to 0.02 mSv (2 mrem) in any one hour, the familiar 2 mR/h barrier. Some allow time-averaging. Use your local rules and your radiation protection adviser's (RPA) or radiation safety officer's (RSO) instructions.

ALARA in practice: collimate every shot, use the lowest workable activity, check the barrier with a survey meter while the source is exposed, wear personal and alarm dosemeters, and survey the projector after every shot. See also the forum thread on safe working distance.

Try it: Dose rate at distance · Barrier distance · Shielding thickness · Half-value layer

Next chapterFilm, digital radiography and choosing a method
Chapter 4 of 4

Film, digital radiography and choosing a method

3 sections · 3 min read

What is the difference between computed radiography (CR) and digital radiography (DR)?

Computed radiography uses flexible phosphor imaging plates that are exposed like film and then read in a laser scanner. Digital radiography uses a digital detector array (DDA), a rigid flat panel that gives an image within seconds; both are judged by basic spatial resolution and signal-to-noise ratio, not film density.

FeatureFilmCRDR
DetectorSilver halide filmReusable storage phosphor plateFlat panel, usually scintillator on amorphous silicon or CMOS
Image readyAfter wet processingAfter scanning, in minutesWithin seconds
Round pipeBends to fitBends to fitRigid; curved and line detectors exist
Quality measuresDensity, IQISRb, SNR, IQISRb, SNR, IQI

Some people say "digital radiography" for any filmless method, CR included; codes keep CR (storage phosphor plates) and DR or DDA (direct readout) apart.

Basic spatial resolution (SRb) is read from a duplex wire IQI (ISO 19232-5 or ASTM E2002) and is about half the total image unsharpness. Signal-to-noise ratio (SNR) is the mean grey value of an even area divided by its standard deviation; ISO 17636-2 normalises it to a reference resolution of 88.6 µm (SNRN) so detectors can be compared. You still place the usual wire or hole IQIs and must still see the essential wire or hole.

SNR rises with dose, so the exposure saving over film shrinks as the required class gets stricter. CR plates lose their latent image with time, so scan promptly. Density has no meaning on a digital image; the forum thread on film density vs CR covers what replaces it. See also the Digital radiography group.

Try it: Basic spatial resolution · Detector pixel size vs IQI

Which codes and standards accept digital radiography?

ASME Section V Article 2 has mandatory appendices for computed radiography with imaging plates and for digital detector systems, and ISO 17636-2 covers digital radiography of welds. Whether a job may use them depends on the code edition the contract names, a qualified procedure and the client's agreement.

  • ASME Section V, Article 2: separate mandatory appendices for CR and for digital detectors, covering the procedure and its demonstration, IQIs, display and storage. Section VIII and B31.3 call up Section V, so digital radiography reaches them through the Section V edition they reference.
  • ISO 17636-2: digital detector techniques for welds in classes A and B, with minimum normalised SNR and maximum basic spatial resolution by thickness, plus the usual IQI requirement. ISO 16371 covers CR systems generally.
  • ASTM: E2446 classifies CR systems, E2445 covers CR performance and long-term stability, and E2597 covers the manufacturer's characterisation of detector arrays. E2033 (CR) and E2698 (DDA) are the examination practices.

Three things catch people out: a contract naming an edition older than the digital rules; image storage (keep the original image, record any processing, agree format and viewer with the client); and personnel, since many written practices treat film, CR and DR as separate techniques needing their own training. See NDT certification questions.

RT or UT for welds: which is better, and can PAUT or TOFD replace radiography?

Neither is better for every weld: RT finds volumetric flaws such as porosity and slag well and leaves an image anyone can audit, while UT, especially PAUT and TOFD, is better at planar flaws such as lack of fusion and cracks and gives their depth and height without a radiation area. Many codes let encoded PAUT or TOFD replace RT when the code edition, a qualified procedure and the client allow it.

FactorRTUT, PAUT, TOFD
Best atPorosity, slag, tungsten, burn-throughLack of sidewall fusion, cracks
Depth and heightNot from a normal shotGiven; TOFD sizes height well
AccessBoth sidesOne side
SafetyRadiation area stops nearby workNo radiation
RecordFilm or digital imageEncoded PAUT and TOFD data can be stored; manual UT leaves little

RT depends on flaw orientation: a crack lying along the beam shows well, but lack of fusion on a bevel face angled away from the beam may be faint or invisible. UT is the reverse: it responds best to planar reflectors facing the beam and is less reliable at characterising scattered porosity. Thick sections favour UT; thin walls and coarse-grained welds need special UT techniques.

In practice, RT stays common on thin and small-bore pipe and where the client wants a picture, while PAUT and TOFD are usual on thick-walled vessels, pipelines and sites where a radiation area would stop work. ASME Code Case 2235 opened the route to ultrasonic examination in lieu of radiography for boiler and pressure vessel work, and several construction codes now carry such rules in their own text. Qualification and acceptance are covered on the PAUT and TOFD questions page.