Half value layer and tenth value layer

Photons are removed from a narrow beam exponentially: I = I0 x e^(-mu x x), where mu is the linear attenuation coefficient of the shield at that photon energy. The thickness that halves the intensity is the half value layer, HVL = ln2 / mu. Because the law is exponential, each successive HVL halves what is left, so n half value layers transmit 2^-n of the incident beam.

The tenth value layer is the same idea to a factor of ten: TVL = ln10 / mu = HVL x log2(10) = 3.322 x HVL. Shielding designers work in TVLs because the attenuation factors needed on a radiography bay are usually several orders of magnitude, and counting in tens is quicker than counting in halves.

Attenuation depends steeply on both photon energy and the atomic number of the shield. At iridium energies lead has an HVL of about 4.8 mm while steel needs 12.7 mm and concrete 44.5 mm for the same effect. At cobalt energies the whole picture stiffens: lead needs 12.5 mm, and lead's advantage over steel narrows because Compton scattering, which scales with electron density rather than Z to the fourth or fifth power, takes over from photoelectric absorption.

These values are narrow-beam figures. In a real broad, uncollimated field, photons that scatter within the shield still emerge and contribute to the dose behind it. That effect is the build-up factor, and it means a shield designed on HVL arithmetic alone always performs worse than the calculation says. See the shielding thickness calculator for how much margin to add.

I / I0 = 2^(-x / HVL) = e^(-mu x x)
HVL = ln2 / mu
TVL = ln10 / mu = 3.3219 x HVL
n = x / HVL half value layers
Broad beam: I = B x I0 x 2^(-x/HVL)

Members-only calculator

Sign in or join free to use the full NDT toolbox.

Sign in View memberships

Notes:
  • Narrow-beam values at the default B = 1. Real broad-beam shields transmit more because of scattered build-up - enter a tabulated build-up factor to include it.
  • Concrete values assume ordinary concrete at 2.35 g/cm3. Barytes and magnetite concretes attenuate far more per millimetre.
  • TVL is derived here as HVL x log2(10) = 3.3219 x HVL.

Reference: NCRP Report No. 49; IAEA Safety Reports Series No. 13; ISO 17636-1:2013

These calculators support — never replace — calculations against the governing code edition and your written procedure. Verify results independently before use.

Related calculators

193 calculations with worked examples

NDT calculators

All calculators

955 discussions · 382 answers

Latest forum discussions

Open the forum
Inspection technician working on pipework at an industrial plant

Hiring?

Post a vacancy where NDT people look first

Reach 5,341 inspection professionals and 1,511 resumes on file.

Sponsors of NDT Inspect
Magnaflux
Sponsor slot open