NDT calculators · PT

Penetrant Testing calculators.

Dwell and process times, temperatures, washing and lighting checks. Each of the 8 shows the governing formula, a worked example and the standard it comes from.

1 works without an account; the other 7 open with a free member account. Join free or sign in.

Liquid penetrant

8 calculators

Core calculations first. Pick a topic or search to narrow them down.

Liquid penetrant 8

Dwell and process times, temperatures, washing and lighting checks.

  • PT Dwell and process times

    Penetrant dwell time

    Minimum penetrant and developer dwell times from ASME V Table T-672 by material and product form, with the standard temperature range check.

    ASME V · ASTM E165 Free

  • PT Conditions and checks

    Penetrant inspection lighting verification

    Checks measured lighting against the code requirements - 1000 µW/cm² UV-A with ambient white light at or below 20 lx for fluorescent, or 1000 lx white light for visible dye.

    ASME V · ASTM E165

  • PT Conditions and checks

    Penetrant temperature qualification check

    Checks part and penetrant temperature against the standard qualified range and shows how far outside it the process sits, which triggers nonstandard temperature qualification.

    ASME V · ASTM E165

  • PT Dwell and process times

    Developer dwell time

    Developer dwell window from the penetrant dwell - half to twice that time, never less than 10 min - with the 10 to 60 min interpretation window.

    ASME V · ASTM E165

  • PT Dwell and process times

    Emulsification time

    Nominal emulsification time windows for post-emulsifiable penetrants - 30 s to 2 min hydrophilic, 10 s to 3 min lipophilic - and the total removal step time.

    ASME V · ASTM E165

  • PT Conditions and checks

    Penetrant drying temperature limits

    Checks part temperature during drying against the 71 °C (160 °F) ASTM limit or the 52 °C (125 °F) ASME V examination limit, with the drying time guide.

    ASTM E165 · ASTM E1417

  • PT Conditions and checks

    Penetrant wash parameters

    Checks rinse water pressure and temperature against the 275 kPa (40 psi) and 10 to 40 °C limits, and flags techniques where water washing is not permitted.

    ASTM E165 · ASTM E1417

  • PT Dwell and process times

    Penetrant process timeline

    Total elapsed time for a complete penetrant examination from pre-clean to post-clean, the earliest interpretation point, and throughput per hour and per shift.

    ASME V · ASTM E165

Formulas are the standard engineering forms. Values taken from codes — IQI classes, allowable stress, dwell tables, acceptance limits — are stated with the edition they come from.

Use at your own risk — verify before you act

These calculators support, and never replace, the judgement of qualified NDT and engineering personnel. Results are provided as is, without warranty of any kind, express or implied, and must be independently verified against the governing code edition named in your contract before being used in any inspection, acceptance, rejection, radiation-safety or fitness-for-service decision. By using them you accept full responsibility for how the results are applied; NDT Inspect, its owners and contributors accept no liability for any loss, damage, injury or death arising from their use or from reliance on them. If a result matters to safety, check it by hand and have it reviewed by a competent person.

Sponsors of NDT Inspect
Magnaflux
Sponsor slot open