Manual UT Acceptance Calculator
Manual ultrasonic testing evaluator with corrected weld geometry families, tee-joint subtypes, acceptance logic, and indication visualization.
Manual UT Acceptance
Crack / LOF / IP = Reject
Tee-Joint Subtypes Rebuilt
Project Information
Acceptance Settings
Acceptance logic used: cracks, lack of fusion, and incomplete penetration are rejected regardless of length. Other linear indications are rejected only when they exceed the reference level and their length exceeds the allowable value for thickness t.
Indication Input
| ID | Indication Type | Start Pos. (mm) | Length (mm) | Depth z from OD / ref face (mm) | X Offset in Weld (mm) | Above Ref? | dB vs Ref | % SH | Allowed Length | Status |
|---|
Evaluation Summary
Input indications
0
Grouped indications
0
Accepted
0
Rejected
0
Evaluation Results
| ID | Members | Type | Start | End | Length | Allowed | Above Ref? | Reason | Status |
|---|
Acceptance Graph
Allowable length
Accept
Reject
Geometry Family & Weld Type
Rebuilt geometry engine: tee-joint subtypes are now separate geometries. Fillet, J-groove, bevel groove, plug, slot, and flare-V are not drawn as the same fake T shape.
Weld Geometry View
Base / member material
Weld metal
Accept
Reject
Weld Length View
0.0 mm
150.0 mm
Raw indications
Grouped indications