Inspection technician working on pipework at an industrial plant

What’s new

The NDT community, live

Updates, photos, documents and polls from members, groups and companies — join the conversation.

The NDT Inspect community

What’s new

  • 36 posts this week
  • 0 online now
  • 5,506 members

What’s new on NDT Inspect

Latest NDT & inspection industry news, jobs and community updates

Live updates from the NDT Inspect community: new NDT job vacancies, product launches from the virtual exhibition, forum discussions and member activity across ultrasonic, radiographic, phased array and every other inspection method. Join free to post and follow.

Share an update with 5,506 NDT professionals…Join free

Members post updates, comment, react and follow the companies they work with. Already a member? Sign in

190 posts in DiscussionsClear

  • luna
    luna started the discussion COVID-19: NDT companies move to virtual showrooms in the forum NDT
    5 years ago
    Discussion

    The corona crisis causes cancelation of conferences and exhibitions. Travelling in general is almost impossible. Vendors and users have reduced meetings in-person and are utilising virtual platforms, where possible.

    NDT companies are moving their stands online. Virtual showrooms let them post company information and product news as simple text messages, presentations, videos or on-demand webinars, and reach inspectors and buyers they can no longer meet at a show.

    Perhaps we will see a renaissance of online conferences and on-demand webinars. During this crisis vendors should benefit from tools like this, and they help keep the conversation of the global NDT community alive, now more than ever.

    We hope that you and your families remain healthy and safe during this time.

    Comment Share
  • luna
    luna started the discussion COVID-19: NDT companies move to virtual showrooms in the forum NDT
    5 years ago
    Discussion

    The corona crisis causes cancelation of conferences and exhibitions. Travelling in general is almost impossible. Vendors and users have reduced meetings in-person and are utilising virtual platforms, where possible. NDT companies are moving their stands online. Virtual showrooms let them post company information and product news as simple text messages, presentations, videos or on-demand webinars, and reach inspectors and buyers they can no longer meet at a show. Perhaps we will see a renaissance of online conferences and on-demand webinars. During this crisis vendors should benefit from tools like this, and they help keep the conversation of the global NDT community alive, now more than ever. We hope that you and your families remain healthy and safe during this time.

    Comment Share
  • arsal
    arsal started the discussion Welding Inspector Posted by Frontier Certification International W.L.L. Job Loca in the forum Jobs and Career Discussion
    5 years ago
    Discussion
    Welding Inspector Posted by Frontier Certification International W.L.L. Job Location: Qatar Minimum Qualification Diploma/B.E in Mechanical/Metallurgical Engineering. Shall be certified welding inspector (CWI) from <div>

    welding society (AWS) or CSWIP 3.1/3.2. Shall have multi discipline NDT level II certification per ASNT (CP-181-91) UT, MPI, PT & Radiography testing with minimum 5 years hands on experience. Minimum 5 years of experience after the certification. Shall have minimum 10 years of experience in Fabrication, Erection and in-service inspection of pressure vessels, Boilers, Furnaces, Heat exchangers, Piping and Tanks etc. Interested candidates plz send your updated cv & certificates to [email protected]

    </div>
    Comment Share
  • kevlin
    Kevlin started the discussion FlexoForm probe issue in the forum Corrosion Mapping
    5 years ago
    Discussion

    Olympus FlexoForm scanner probe (part number 7.5L64-64X7-FA1) stopped working after a year of use for corrosion mapping and I noticed that plastic protecting the probe has separated from probe itself as per images attached. Now, any recommendations on how to fix this issue?

    Would you agree that using heat gun could help or any other way? We did order another probe but would like to fix this one and have it as spare. Also, each cost 17K+ USD.

    Your help is much appreciated.

    👍2
    Comment Share
  • NDT Inspect (admin)
    NDT-Inspect started the discussion What is Phased Array Ultrasonics PAUT? in the forum Phased Array
    5 years ago
    Discussion
    The focus of the ultrasonic beam is on a time delay between several piezoelectric crystals which can transmit and receive independently at different times, creating a constructive interference wavefront that allows energy to focus on the depth at which the sample is examined. The Calculator determines the delay time between the fire group element that generates the required beam shape (considered a wedge probe) and the characteristic acoustic properties and geometry of the test material.

    Phased array ultrasound is an inspection method that uses probes with several small transducer pulses to control the focus of a vibrating beam. Numerous small elements are excited with different time delays so that the beam can be directed at different angles and concentrated at different depths by multiplying the length of a long array, creating an electronic movement of the beam. In varying the timing, for example, pulses of the transducers leave the grid with each delay with a pattern of constructive interference, which leads to quasi-plane ultrasonic radiation at a specified angle depending on the progressive delay.

    Phased array ultrasound (PAUT) provides improved coverage of any component welded in one fixed or multiple positions, including beam coverage of complex geometries for which conventional ultrasonic techniques are insufficient. Phased array beams sweep over an object like a searchlight, producing writable images that reveal defects hidden in the weld structure, similar to ultrasound in our sonograms used in hospitals. In a smaller form factor, bead inspection of phase array equipment can be automated to scan circumferential and axial welds of mechanical systems for high volume inspection and manufacturing applications.

    Phased array ultrasonic transducers (PAUTs) are an effective method of carrying out inspections in the form of imaging and non-destructive inspections of structures and materials. Phased array systems are increasingly being used in the industrial environment to provide new, in-depth visualizations and information for standard ultrasonic testing including profiling, welding inspection, crack detection and bonding.

    Phase arrays can perform the function of conventional ultrasound and can be used for a wide range of inspection and measurement applications including medical imaging and non-destructive industrial testing (NDT). In the most basic sense, phased array systems use wave physics principles to phase the different time series of the outgoing ultrasonic pulses in such a way that the individual waves generated by the elements of the array in the front combine and add or cancel energy in a predictable way to control the shape of the sound beam.

    Phased array systems use phase laws of wave physics to alter the time range of pulses in this way by separating and merging the waves before and after each element of the array, adding or canceling energy in an expected manner to guide the contours of the beam. Unlike conventional fault detectors, phase array systems sweep the beam across a series of refracted angles rather than along a linear path focusing on a number of different depths increasing the flexibility and ability of inspection systems. This is achieved by pulsing the individual probe elements at different times. This means that a transmitter only has to inspect each component at different angles, which is faster than the standard beam angle in an UT, and can display the specimen cross-section in real time, making interpretation easier. With PAUTs with several elements, each pulse generates a different beam shape, such as linear, focused, sectoral, etc.

    Unlike conventional one-element converters, which combine the effects of the beam components hitting its range, phase field converters sort the return wave front according to the arrival time and amplitude of each element. Unlike beam phase array probes, which are controllable, they consist of several smaller elements, each pulsed by a computer to calculate the timing.

    Multielement transmitters enable ultrasonic testing of complex shapes. A one-element probe without a phase array, also known as a monolithic probe, emits a beam in a fixed direction. In order to test and interrogate large amounts of material, conventional probes scan the area of interest with a moving, rotating and sweeping beam. The use of phased array probes which are in direct contact with components mounted on hard wedges, water delay pipes or wheel probes allows inspectors to inspect large areas with a very high resolution for corrosion, cracks and other defects. Optimized beam focusing angles allow fast scanning of moving parts, multi-angle inspection, and inspection of materials with complex geometries. Inspection speed is improved compared to conventional probes, and phase arrays allow the user to alter the shape of the ultrasonic beam focal point to optimize inspection.

    The use of electronic scanning (firing successive groups of elementary rays or PAUTs) reduces the need for mechanical scanning, reducing inspection time. The ultrasonic method has been used for many years to investigate defects in composite materials. This is an X-ray technique with an advanced NDT detector system. Phase array probes can replace multiple conventional ultrasonic probes, simplifying complex procedures and eliminating the need to set up and calibrate multiple probes.

    Phased Array Ultrasonic Testing (PAUT) is an advanced non-destructive testing technique that uses a series of UT ( Ultrasonic Probes), consisting of multiple small elements that are pulsed by a computer to determine the time and phase. PAUT is a focused inspection technique designed to integrate beam technology to detect complex geometries and size defects. There are four major differences between conventional UT and PAUT: PAUT PAUT, as it is commonly called, is a non-ESTructive test method that uses ultrasonic waves (radio frequency sound waves) to detect defects and cracks in materials of any thickness.

    Comment Share
  • hannah-hong
    Hannah Hong Hiring started the discussion SIUI SyncScan 3 PAUT in the forum Product Exhibition
    5 years ago
    Discussion
    SyncScan 3 is 64:128PR PAUT flaw detector with total focusing method (TFM) and 4-ch TOFD, which bring more possibilities for your inspection in oil & gas, transportation, aerospace, shipbuilding, manufacturing industries.


    http://www.siui.com/ax0/a/chanpinzhongxin/wusunjiance/20210608/376.html


    Comment Share
  • hannah-hong
    Hannah Hong Hiring started the discussion SIUI Equipment Manufacturer in the forum Company Groups
    5 years ago
    Discussion

    SIUI is an ISO certified company and has been dedicated to R&D, manufacture and sales of ultrasonic products for more than 40 years. Compliant with EN12668 and EN15317 standards, SIUI is able to provide a wide range of ultrasonic products, including PA flaw detectors, conventional ultrasonic flaw detectors, thickness gauges, probes, crawlers, calibration blocks, etc.

    /companies/siui/

    http://www.siui.com/

    Comment Share
  • Doug
    doug started the discussion PAUT Interpretation Test :) in the forum Phased Array
    5 years ago
    Discussion

    How many of us PAUT inspectors know what type of defect this is? 😀

    Both images represent one defect just in different place/ position.

    👍3
    Comment Share
  • Doug
    doug started the discussion EVALUATING THE VARIABLES THAT IMPACT ULTRASONIC TESTING in the forum Phased Array
    5 years ago
    Discussion

    /evaluating-the-variables-that-impact-ultrasonic-testing/


    👍2
    Comment Share
  • Doug
    doug started the discussion API 571 for Inspectors in the forum Codes and Standards
    5 years ago
    Discussion

    /api-571-for-inspectors/

    👍1
    Comment Share
  • Doug
    doug started the discussion Phased array instruments and ability to define anisotropic velocity? in the forum Phased Array
    5 years ago
    Discussion

    Does anyone know of any PAUT equipment that allows you to define velocity as a function of angle? I believe that Olympus PipeWIZARD V4 has this capability, but beyond that I'm not aware of any regular sort of, "field portable" PAUT set that permits you define velocity as a function of angle (a "velocity vector", if you will).

    Last year I came across this problem first hand while inspecting welds on TMCP pipeline steel. Ed Ginzel and I got a sample, and figured out a very simple way to calibrate for it using two phased array probes in pitch-catch, placed on the pipe material. It was much more common than we thought. I fear they may be many PAUT crews out there looking at "melting S-scans", and plotting defects incorrectly. This is something that we hope (one day ) to be integrated into field portable PAUT equipment (hint hint my PAUT OEMs!).

    The first paper explains the procedure:
    “Calibration for Anisotropic Effects on Shear Wave Velocity for Improvements of Weld Inspections in TMCP Steels”

    Then we published two more papers because we simply couldn't stop ourselves (too interesting!):
    “Visualisation of Acoustic Birefringence”

    “Velocity determination using time-stops in photoelastic imaging”

    I also did a video explaining the simple calibration setup:
    https://youtu.be/aPxKdGmMUmM

    👍2
    Comment Share
  • chris
    chris started the discussion Is NDT the career for me? in the forum NDT
    5 years ago
    Discussion

    I have been asked this question many times. Below is an example of one guy asking this question.

    What do you think about NDT carrer and would you go different path if you had an option?

    Hi all,
    I graduated in 2017 with a BENG in Mechanical Engineering, since then I have worked in finance as it was the first job I was able to get out of university. I’m 26 and I have realised that life is too short to waste years on a career in something I’m not passionate about. I heard about NDT whilst exploring jobs that would allow me to use my degree and eventually go down the rope access route.
    It would be great to hear some opinions on:
    Would my degree be useful in an NDT career?
    Would NDT allow for travelling/working abroad?
    What kind of salary would you expect for someone at entry level up through level 1, 2 and 3?
    Does NDT work require you to be away from home for long periods of time?
    What does a typical day in the life of an NDT technician consist of?
    Any other advice or pointers would be much appreciated.
    Thanks
    Scott

    Comment Share
  • nde
    nde started the discussion ASME SEC-V : 2019 /ASME SNT TC 1A-2016 Edition NDT Audit in the forum Codes and Standards
    5 years ago
    Discussion

    ASME QCM Manual clause No.: XX - NDE Personal qualification to meet the requirement and ASNT -SNT -TC-IA Code adopted edition-2016 and as amended by the Mandatory appendix -II & III to article -1 of ASME SEC-V Code compliance -2019.

    NDT written Practice established (RT/UT/MT/PT) : Training, examination, Qualification and Certification clause No.: XXX .NDE Level-III “ Education, Training and Experience requirements for NDE Level-III are satisfied if the individual holds a current ASNT NDT Level-III Certificate in the specific NDE Method”.

    Separate VT written practice established and this procedure was prepared by AWS-CWI/CSWIP 3.1 Welding Inspector. Also noticed that ASNT SNT-TC-IA Reference was not included in the written practice for training hours, qualification and certification.
    Mandatory Appendix-III ASME: 4.4 Article -1: Paragraph 4.3.3 an NDE Level III individual shall have sufficient technical knowledge and skills to develop, qualify, and approve procedures, establish and approve techniques, interpret codes, standards, specifications, and procedures; and designate the NDE methods, techniques, and procedures to be used. ---------------. The NDE Level III, in the methods in which certified, shall have sufficient technical knowledge and skills to be capable of training and examining NDE Level I, II, and III personnel for certification in those methods.


    Mandatory Appendix-III ASME Sec.V: 1.1 Paragraph 1.4 when developing a written practice as required in ASME Section V, the employer shall review and include the detailed recommendations presented in SNT-TC-1A–2016 and ASME Section V including this Mandatory Appendix. Modifications that reduce or eliminate basic provisions of the program such as training, experience, testing, and recertification shall not be allowed.

    Mandatory Appendix-III ASME Sec.V: 3.0 As described in SNT-TC-1A paragraph 3.0 Non-destructive Testing Methods subparagraph 3.1.
    3.1 Paragraph 3.1 Qualifications and certifications of NDE personnel in accordance with ASME Section V
    are applicable to the following methods:
    Acoustic Emission Testing
    Electromagnetic Testing
    Guided Wave Testing
    Leak Testing
    Liquid Penetrant Testing
    Magnetic Particle Testing
    Radiographic Testing
    Visual Testing and
    Ultrasonic Testing

    I Went for NDT Audit and issued NCR: Non -conformance Issued to Vessel Manufacturer as per ASME SEC-VIII DIV.1:
    Case -1

    A) Visual Examination Work procedure and Written practice for Visual Inspector established and reviewed/Certified by NDT level-3 (RT/UT/MT/PT) Methods. It was not meeting as per ASME SEC-V Mandatory appendix -III of Arctile-1 and this procedure was prepared by AWS-CWI/CSWIP 3.1 Welding Inspector. Also noticed that ASNT SNT-TC-IA Reference was not included in the written practice and training hours, qualification and certification as per written practice.

    B) Visual Examination: ASME Article -9 Visual Testing demonstrated (Essential /Non-Essential Variables) and found that no evidence of NDT VT level-III individual holds a current ASNT NDT Level-III Certificate in the specific NDE Method as per ASME SNT-TC-IA: 2016 Edition requirement.

    The above NCR denied by code user ASME SEC-VIII DIV.I and Response was :
    “VT Demonstration- What demonstration we have done for VT, Level -III involvement is not required as per our Code of Construction”.

    Case -2 : Hydro static pressure Test was for a Pressure Vessel manufacture as per Pressure Test Procedure. It was accepted by concern Inspectors.
    Auditor was asked to Manufacture : Pressure Test is coming under Leak Testing Method (NDT) as a Pressure Change Test technique. It was observed that no demonstration of ASME SEC-V Article -10 and no training, qualification and certification was not established in your written practice except NDT -RT/UT/MT/PT. No NDT level -3 reviewed and approved your testing procedure. It was not meeting ASME SEC-V: 2017 /ASNT TC-1A : 2016 (NDE Personal qualification to meet the requirement and ASNT -SNT -TC-IA Code adopted edition-2016 and as amended by the Mandatory appendix -II & III to article -1 of ASME SEC-V Code compliance -2019.)

    Manufacture reply : Declined NCR
    “Hydrostatic Test and Pneumatic Test - what is written in our QCM and Procedure is in accordance with AME Section I, VIII Division 1,&2 , ASME B31.1 and NBIC Code (Repair and Alteration) which do not refer ASME Section V , Articl-1 and 10 for carryout pressure Test. So, It is not required to make any changes in our established System” .

    Please any one advice to me the above cases .It is acceptable as per Manufacturer standpoint of view or as per Auditor point is it acceptable to take decision accordingly?

    👍1
    Comment Share
  • chris
    chris started the discussion MPI for inspecting the inside diameter of tubes for transverse oriented defects in the forum MPI
    5 years ago
    Discussion

    Dear Experts,
    How to inspect the inside diameter of ferromagnetic heavy wall pipes or API Casing hanger tubes by Magnetic particle testing for defects oriented in transverse direction.

    Transverse defects at OD can be covered by coil shot/flexible cable wrap units by employing longitudinal magnetization technique.

    Longitudinal defects at ID can be detected by central conductor technique by circular magnetization and some extent at OD by using high current.

    Is there any effective way to detect transverse defects at ID of pipe?

    Thanks

    Comment Share
  • chris
    chris started the discussion Dynamic Depth Focussing in the forum Phased Array
    5 years ago
    Discussion

    I would like to ask if anybody know how i may apply Dynamic Depth Focusing (DDF) in the Omniscan MX2?

    Does it possible with the MX2 unit or we need to use another unit in order to apply this technique?

    Thanks

    👍2 1 comment
    Comment Share
    noizyboy
    noizyboy

    For dynamic focusing in depth, the simplest version of TomoView is enough, or you can purchase only the Advanced Phased Array Calculator.
    Please also note that dynamic focusing is not required for most ultrasonic scanning tasks.  It is enough to create several groups (sounding schemes) with focusing at different depths (or on different parts of the weld)

    5 years ago
  • nde
    nde started the discussion ASME B31.3 ACCEPTANCE CRITERIA in the forum Codes and Standards
    5 years ago
    Discussion

    Dear All,


    Please refer below for ASME B31.3 acceptance criteria. To reject any indication i need to comply 3 rules :-

    1. It must be linear indication
    2. The indication level must be above reference level
    3. Comply with Rejectable length.

    If i never comply with one of the above criteria i cant reject any indcation. How about Lack of sidewall fusion , lack of penetration and crack which is consider as a serious indication? Do i still need to follow this 3 rules or can i reject this indication since its a serious indication? I am just concern about small thickness and please advice. I just found one lack of sidewall fusion which is :-

    Length :4mm
    Amplitude level : 50% DAC
    Material thickness : 5.49 ( 3" sch 40)



    ASME B31.3-ACCEPTANCE CRITERIA

    344.6.2 Acceptance Criteria. A linear-type discontinuity
    is unacceptable if the amplitude of the indication
    exceeds the reference level and its length exceeds
    (a) 6 mm (1⁄4 in.) for Tw ≤ 19 mm (3⁄4 in.)
    (b) Tw/3 for 19 mm < Tw ≤ 57 mm (21⁄4 in.)
    (c) 19 mm for Tw > 57 mm

    Comment Share
  • chris
    chris started the discussion PAUT probe for casting surface? in the forum Phased Array
    5 years ago
    Discussion

    Hi every professional NDT engineer,
    I have not the experience for PAUT on casting structures/welds, as you know that casting surface is not eveness, so always lose data, or the sensitivity level. I suppose the hydroform probe is good choice, but I did not find out this kind of probe from OLYMPUS, it will be great if you can share your precious experience. thanks a lot!

    👍1
    Comment Share
  • chris
    chris started the discussion PAUT Scanning plan for welding joint ISO13588 in the forum Phased Array
    5 years ago
    Discussion

    Hi Everyone,
    my question is scanning plan for welding joint according to ISO13588:2019.
    please read uploaded table 2 of ISO 13588, in this table, only single V type joint is stipulated, no cases for doube V, or "K" joint, and no description for cases with thick plate.
    I hope the perfect one is annex A of ISO17640.
    so the problem is nothing to follow, could you (everyone experienced master) share something, so that new guy like me could find the way?
    thanks a lot here.

    👍2
    Comment Share
  • chris
    chris started the discussion Rope Access Inspection Guidebook Sample in the forum Rope Access
    5 years ago
    Discussion

    /rope-access-inspection-guidebook-sample/

    Work file for logged in members can be downloaded in Rope Acces documents section.

    Comment Share
  • chris
    chris started the discussion Pipeline Corossion and Inspection Methods in the forum Pipeline Inspection
    5 years ago
    Discussion

    Some Pipeline Inspection Tools are used prior and during the construction and preparation process of the Pipeline, and other inspection methods have a great utility during the pipeline’s function also. We are going to explore in this work both aplicable Pipeline Inspection Methods, through various NDT/NDE inspection methods as well as destructive testing.


    Full article in our blog section: /pipeline-corossion-and-inspection-methods/

    Comment Share
  • chris
    chris started the discussion Liquid Penetrant Testing Introduction in the forum Dye Penetrant Inspection
    5 years ago
    Discussion

    Liquid penetrant testing is one of the oldest and simplists NDT methods where its earliest versions (using kerosene and oil mixture) dates back to the 19th century. This method is used to reveal surface discontinuities by bleedout of a colored or fluorescent dye from the flaw. The technique is based on the ability

    of a liquid to be drawn into a “clean” surface discontinuity by capillary action. After a period of time called the “dwell time”, excess surface penetrant is removed and a developer applied. This acts as a blotter that draws the penetrant from the discontinuity to reveal its presence.

    The advantage that a liquid penetrant inspection offers over an unaided visual inspection is that it makes defects easier to see for the inspector where that is done in two ways:

    It produces a flaw indication that is much larger and easier for the eye to detect than the flaw itself. Many flaws are so small or narrow that they are undetectable by the unaided eye (a

    person with a perfect vision can not resolve features smaller than 0.08 mm).

    It improves the detectability of a flaw due to the high level of contrast between the indication and the background which helps to make the indication more easily seen (such as a red indication on a white background for visable penetrant or a penetrant that glows under ultraviolate light for flourecent penetrant).

    Liquid penetrant testing is one of the most widely used NDT methods. Its popularity can be attributed to two main factors: its relative ease of use and its flexibility. It can be used to inspect almost any material provided that its surface is not extremely rough or porous. Materials that are commonly inspected using this method include; metals, glass, many ceramic materials, rubber and plastics.

    However, liquid penetrant testing can only be used to inspect for flaws that break the surface of the sample (such as surface cracks, porosity, laps, seams, lack of fusion, etc.).

    Steps of Liquid Penetrant Testing

    The exact procedure for liquid penetrant testing can vary from case to case depending on several factors such as the penetrant system being used, the size and material of the component being inspected, the type of discontinuities being expected in the component and the condition and environment under which the inspection is performed. However, the general steps can be summarized as follows:

    Surface Preparation: One of the most critical steps of a liquid penetrant testing is the surface preparation. The surface must be free of oil, grease, water, or other contaminants that may prevent penetrant from entering flaws. The sample may also require etching if mechanical operations such as machining, sanding, or grit blasting have been performed. These and other mechanical operations can smear metal over the flaw opening and prevent the penetrant from entering.Penetrant Application: Once the surface has been thoroughly cleaned and dried, the penetrant material is applied by spraying, brushing, or immersing the part in a penetrant bath.


    Penetrant Dwell: The penetrant is left on the surface for a sufficient time to allow as much penetrant as possible to be drawn from or to seep into a defect. Penetrant dwell time is the total time that the penetrant is in contact with the part surface. Dwell times are usually recommended by the penetrant producers or required by the specification being

    followed. The times vary depending on the application, penetrant materials used, the material, the form of the material being inspected, and the type of discontinuity being inspected for.

    Minimum dwell times typically range from five to 60 minutes. Generally,

    there is no harm in using a longer penetrant dwell time as long as the penetrant is not allowed to dry. The ideal dwell time is often determined by experimentation and may be very specific to a particular application.

    Excess Penetrant Removal: This is the most delicate part of the inspection procedure because the excess penetrant must be removed from the surface of the sample while removing as little penetrant as possible from defects.

    Depending on the penetrant system used, this step may involve cleaning with a solvent, direct rinsing with water, or first treating the part with an emulsifier and then rinsing with water.

    Developer Application: A thin layer of developer is then applied to the sample to draw penetrant trapped in flaws back to the surface where it will be visible. Developers come in a variety of forms that may be applied by dusting (dry powders), dipping, or spraying (wet developers).

    Indication Development: The developer is allowed to stand on the part surface for a period of time sufficient to permit the extraction of the trapped penetrant out of any surface flaws. This development time is usually a minimum of 10 minutes. Significantly longer times may be necessary for tight cracks.Inspection: Inspection is then performed under appropriate lighting to detect indications from any flaws which may be present.Clean Surface: The final step in the process is to thoroughly clean the part surface to remove the developer from the parts that were found to be acceptable.Advantages and Disadvantages

    The primary advantages and disadvantages when compared to other NDT methods are:

    Advantages

    High sensitivity (small discontinuities can be detected).Few material limitations (metallic and nonmetallic, magnetic and nonmagnetic, and conductive and nonconductive materials may be inspected).Rapid inspection of large areas and volumes.Suitable for parts with complex shapes.Indications are produced directly on the surface of the part and constitute a visual representation of the flaw.Portable (materials are available in aerosol spray cans)Low cost (materials and associated equipment are relatively inexpensive)

    Disadvantages

    Only surface breaking defects can be detected.Only materials with a relatively nonporous surface can be inspected.Pre-cleaning is critical since contaminants can mask defects.Metal smearing from machining, grinding, and grit or vapor blasting must be removed.The inspector must have direct access to the surface being inspected.Surface finish and roughness can affect inspection sensitivity.Multiple process operations must be performed and controlled.Post cleaning of acceptable parts or materials is required.Chemical handling and proper disposal is required.Penetrants

    Penetrants are carefully formulated to produce the level of sensitivity desired by the inspector. The penetrant must possess a number of important characteristics:

    spread easily over the surface of the material being inspected to provide complete and even coverage.be drawn into surface breaking defects by capillary action.remain in the defect but remove easily from the surface of the part.remain fluid so it can be drawn back to the surface of the part through the drying and developing steps.be highly visible or fluoresce brightly to produce easy to see indications.not be harmful to the material being tested or the inspector.

    Penetrant materials are not designed to perform the same. Penetrant manufactures have developed different formulations to address a variety of inspection applications. Some applications call for the detection of the smallest defects possible while in other

    applications, the rejectable defect size may be larger. The penetrants that are used to detect the smallest defect will also produce the largest amount of irrelevant indications.

    Standard specifications classify penetrant materials according to their physical characteristics and their performance.

    Penetrant materials come in two basic types:

    Type 1 – Fluorescent Penetrants: they contain a dye or several dyes that fluoresce when exposed to ultraviolet radiation.

    Type 2 – Visible Penetrants: they contain a red dye that provides high contrast against the white developer background.

    Fluorescent penetrant systems are more sensitive than visible penetrant systems because the eye is drawn to the glow of the fluorescing indication. However, visible penetrants do not require a darkened area and an ultraviolet light in order to make an inspection.

    Penetrants are then classified by the method used to remove the excess penetrant from the part. The four methods are:

    Method A – Water Washable: penetrants can be removed from the part by rinsing with water alone. These penetrants contain an emulsifying agent (detergent) that makes it possible to wash the penetrant from the part surface with water alone.

    Water washable penetrants are sometimes referred to as self-emulsifying systems.

    Method B – Post-Emulsifiable, Lipophilic: the penetrant is oil soluble and interacts with the oil-based emulsifier to make removal possible.

    Method C – Solvent Removable: they require the use of a solvent to remove the penetrant from the part.

    Method D – Post-Emulsifiable, Hydrophilic: they use an emulsifier that is a water soluble detergent which lifts the excess penetrant from the surface of the part with a water wash.

    Penetrants are then classified based on the strength or detectability of the indication that is produced for a number of very small and tight fatigue cracks. The five sensitivity levels are:

    Level ½ – Ultra Low Sensitivity Level 1 – Low Sensitivity

    Level 2 – Medium Sensitivity Level 3 – High Sensitivity

    Level 4 – Ultra-High Sensitivity

    The procedure for classifying penetrants into one of the five sensitivity levels uses specimens with small surface fatigue cracks. The brightness of the indication produced is measured using a photometer.

    Developers

    The role of the developer is to pull the trapped penetrant material out of defects and spread it out on the surface of the part so it can be seen by an inspector. Developers used with visible penetrants create a white background so there is a greater degree of contrast between the indication and the surrounding background. On the other hand, developers used with fluorescent penetrants both reflect and refract the incident ultraviolet light, allowing more of it to interact with the penetrant, causing more efficient fluorescence.

    According to standards, developers are classified based on the method that the developer is applied (as a dry powder, or dissolved or suspended in a liquid carrier). The six standard forms of developers are:

    Form a – Dry Powder Form b – Water Soluble

    Form c – Water Suspendable

    Form d – Nonaqueous Type 1: Fluorescent (Solvent Based) Form e – Nonaqueous Type 2: Visible Dye (Solvent Based) Form f – Special Applications

    Dry Powder

    Dry powder developers are generally considered to be the least sensitive but they are inexpensive to use and easy to apply. Dry developers are white, fluffy powders that can be applied to a thoroughly dry surface in a number of ways; by dipping parts in a container of developer, by using a puffer to dust parts with the developer, or placing parts in a dust cabinet where the developer is blown around. Since the powder only sticks to areas of indications since they are wet, powder developers are seldom used for visible inspections.

    Water Soluble

    As the name implies, water soluble developers consist of a group of chemicals that are dissolved in water and form a developer layer when the water is evaporated away. The best method for applying water soluble developers is by spraying it on the part. The part can be wet or dry. Dipping, pouring, or brushing the solution on to the surface is sometimes used but these methods are less desirable. Drying is achieved by placing the wet but well drained part in a recirculating, warm air dryer with the temperature 21°C. Properly developed parts will have an even, pale white coating over the entire surface.

    Water Suspendable

    Water suspendable developers consist of insoluble developer particles suspended in water. Water suspendable developers require frequent stirring or agitation to keep the particles from settling out of suspension. Water suspendable developers are applied to parts in the same manner as water soluble developers then the parts are dried using warm air.

    Nonaqueous

    Nonaqueous developers suspend the developer in a volatile solvent and are typically applied with a spray gun. Nonaqueous developers are commonly distributed in aerosol spray cans for portability. The solvent tends to pull penetrant from the indications by solvent action. Since the solvent is highly volatile, forced drying is not required.

    Special Applications

    Plastic or lacquer developers are special developers that are primarily used when a permanent record of the inspection is required.

    Preparation of Part

    One of the most critical steps in the penetrant inspection process is preparing the part for inspection. All coatings, such as paints, varnishes, plating, and heavy oxides must be removed to ensure that defects are open to the surface of the part. If the parts have been machined, sanded, or blasted prior to the penetrant inspection, it is possible that a thin layer of metal may have smeared across the surface and closed off defects. Also, some cleaning operations, such as steam cleaning, can cause metal smearing in softer materials. This layer of metal smearing must be removed before inspection.

    Penetrant Application and Dwell Time

    The penetrant material can be applied in a number of different ways, including spraying, brushing, or immersing the parts in a penetrant bath. Once the part is covered in penetrant it must be allowed to dwell so the penetrant has time to enter any defect that

    is present.

    There are basically two dwell mode options:

    Immersion-dwell: keeping the part immersed in the penetrant during the dwell period.Drain-dwell: letting the part drain during the dwell period (this method gives better sensitivity).Penetrant Dwell Time

    Penetrant dwell time is the total time that the penetrant is in contact with the part surface. The dwell time is important because it allows the penetrant the time necessary to seep or be drawn into a defect. Dwell times are usually recommended by the penetrant producers or required by the specification being followed. The time required to fill a flaw depends on a number of variables which include:

    The surface tension of the penetrant.The contact angle of the penetrant.The dynamic shear viscosity of the penetrant.The atmospheric pressure at the flaw opening.The capillary pressure at the flaw opening.The pressure of the gas trapped in the flaw by the penetrant.The radius of the flaw or the distance between the flaw walls.The density or specific gravity of the penetrant.Microstructural properties of the penetrant.

    The ideal dwell time is often determined by experimentation and is often very specific to a particular application. For example, the table shows the dwell time requirements for steel parts according to some of the commonly used specifications.

    Penetrant Removal Process

    The penetrant removal procedure must effectively remove the penetrant from the surface of the part without removing an appreciable amount of entrapped penetrant from the discontinuity. If the removal process extracts penetrant from the flaw, the flaw indication will be reduced by a proportional amount. If the penetrant is not effectively removed from the part surface, the contrast between the indication and the background will be reduced.

    Removal Method

    As mentioned previously, penetrant systems are classified into four types according to the method used for excess penetrant removal.

    Method A: Water-WashableMethod B: Post-Emulsifiable, LipophilicMethod C: Solvent RemovableMethod D: Post-Emulsifiable, Hydrophilic

    Method C, Solvent Removable, is used primarily for inspecting small localized areas. This method requires hand wiping the surface with a cloth moistened with the solvent remover, and is, therefore, too labor intensive for most production situations.

    Method A, Water-Washable, is the most economical to apply of the different methods and it is easy to use. Water-washable or self-emulsifiable penetrants contain an emulsifier as an integral part of the formulation. The excess penetrant may be removed from the object surface with a simple water rinse.

    When removal of the penetrant from the defect due to over-washing of the part is a concern, a post-emulsifiable penetrant system can be used. The post-emulsifiable methods are generally only used when very high sensitivity is needed. Post- emulsifiable penetrants require a separate emulsifier to breakdown the penetrant and make it water washable. The part is usually immersed in the emulsifier but hydrophilic emulsifiers may also be sprayed on the object. Brushing the emulsifier on to the part is not recommended either because the bristles of the brush may force emulsifier into discontinuities, causing the entrapped penetrant to be removed. The emulsifier is allowed sufficient time to react with the penetrant on the surface of the part but not given time to make its way into defects to react with the trapped penetrant.

    Controlling the reaction time is of essential importance when using a post-emulsifiable system. If the emulsification time is too short, an excessive amount of penetrant will be left on the surface, leading to high background levels. If the emulsification time is too long, the emulsifier will react with the penetrant entrapped in discontinuities, making it possible to deplete the amount needed to form an indication.

    The hydrophilic post-emulsifiable method (Method D) is more sensitive than the lipophilic post-emulsifiable method (Method B). The major advantage of hydrophilic emulsifiers is that they are less sensitive to variation in the contact and removal time.

    When using an emulsifiable penetrant is used, the penetrant inspection process includes the following steps (extra steps are underlined): 1. pre-clean part, 2. apply penetrant and allow to dwell, 3. pre-rinse to remove first layer of penetrant, 4. apply hydrophilic emulsifier and allow contact for specified time, 5. rinse to remove excess penetrant, 6. dry part, 7. apply developer and allow part to develop, and 8. inspect.

    Rinse Method and Time for Water-Washable Penetrants

    The method used to rinse the excess penetrant from the object surface and the time of the rinse should be controlled so as to prevent over-washing. It is generally

    recommended that a coarse spray rinse or an air-agitated, immersion wash tank be used. When a spray is being used, it should be directed at a 45° angle to the part surface so as to not force water directly into any discontinuities that may be present. The spray or immersion time should be kept to a minimum through frequent inspections of the remaining background level.

    Hand Wiping of Solvent Removable Penetrants

    When a solvent removable penetrant is used, care must also be taken to carefully remove the penetrant from the part surface while removing as little as possible from the flaw. The first step in this cleaning procedure is to dry wipe the surface of the part in one direction using a white, lint-free, cotton rag. One dry pass in one direction is all that should be used to remove as much penetrant as possible. Next, the surface should be wiped with one pass in one direction with a rag moistened with cleaner. One dry pass followed by one damp pass is all that is recommended. Additional wiping may sometimes be necessary; but keep in mind that with every additional wipe, some of the entrapped penetrant will be removed and inspection sensitivity will be reduced.

    Use and Selection of a Developer

    The use of developer is almost always recommended. The output from a fluorescent penetrant is improved significantly when a suitable powder developer is used. Also, the use of developer can have a dramatic effect on the probability of detection of an inspection.

    Nonaqueous developers are generally recognized as the most sensitive when properly applied. However, if the thickness of the coating becomes too great, defects can be masked. The relative sensitivities of developers and application techniques as ranked in Volume II of the Nondestructive Testing Handbook are shown in the table below.

    The following table lists the main advantages and disadvantages of the various developer types.

    Quality & Process Control

    Quality control of the penetrant inspection process is essential to get good and consistent results. Since several steps and materials are involved in the inspection process, there are quality control procedures for each of them.

    Temperature Control

    The temperature of the penetrant materials and the part being inspected can have an effect on the results. Temperatures from 27 to 49°C are reported in the literature to produce optimal results. Many specifications allow testing in the range of 4 to 52°C. Raising the temperature beyond this level will significantly raise the speed of evaporation of penetrants causing them to dry out quickly.

    Since the surface tension of most materials decrease as the temperature increases, raising the temperature of the penetrant will increase the wetting of the surface and the capillary forces. Of course, the opposite is also true, so lowering the temperature will have a negative effect on the flow characteristics.

    Penetrant Quality Control

    The quality of a penetrant inspection is highly dependent on the quality of the penetrant materials used. Only products meeting the requirements of an industry specification, such as AMS 2644, should be used. Deterioration of new penetrants primarily results from aging and contamination. Virtually all organic dyes deteriorate over time, resulting in a loss of color or fluorescent response, but deterioration can be slowed with proper storage. When possible, keep the materials in a closed container and protect from freezing and exposure to high heat.

    Contamination can occur during storage and use. Of course, open tank systems are much more susceptible to contamination than are spray systems. Regular checks must be performed to ensure that the material performance has not degraded. When the penetrant is first received from the manufacturer, a sample of the fresh solution should be collected and stored as a standard for future comparison. The standard specimen should be stored in a sealed, opaque glass or metal container. Penetrants that are in-use should be compared regularly to the standard specimen to detect any changes in properties or performance.

    Dwell Quality Control

    Dwell times are usually recommended by the penetrant producer or required by the specification being followed. The only real quality control required in the dwell step of the process is to ensure that a minimum dwell time is reached. There is no harm in allowing a penetrant to dwell longer than the minimum time as long as the penetrant is not allowed to dry on the part.

    Emulsifier Path Quality Control

    Quality control of the emulsifier bath is important and it should be performed per the requirements of the applicable specification.

    Lipophilic Emulsifiers

    Lipophilic emulsifiers mix with penetrants but when the concentration of penetrant contamination in the emulsifier becomes too great, the mixture will not function effectively as a remover. Standards require that lipophilic emulsifiers be capable of 20% penetrant contamination without a reduction in performance. When the cleaning action of the emulsifier becomes less than that of new material, it should be replaced.

    Hydrophilic Emulsifiers

    Hydrophilic emulsifiers have less tolerance for penetrant contamination. The penetrant tolerance varies with emulsifier concentration and the type of contaminating penetrant. In some cases, as little as 1% (by volume) penetrant contamination can seriously affect the performance of an emulsifier.

    Emulsifier Concentration and Contact Time

    The optimal emulsifier contact time is dependent on a number of variables that include the emulsifier used, the emulsifier concentration, the surface roughness of the part being inspected, and other factors. Usually some experimentation is required to select the proper emulsifier contact time.

    Wash Quality Control

    The wash temperature, pressure and time are three parameters that are typically controlled in penetrant inspection process specification. A coarse spray or an immersion wash tank with air agitation is often used. When the spray method is used, the water pressure is usually limited to 276 kPa. The temperature range of the water is

    usually specified as a wide range (e.g., 10 to 38°C). The wash time should only be as long as necessary to decrease the background to an acceptable level. Frequent visual checks of the part should be made to determine when the part has been adequately rinsed.

    Drying Process Quality Control

    The temperature used to dry parts after the application of an aqueous wet developer or prior to the application of a dry powder or a nonaqueous wet developer, must be controlled to prevent drying in the penetrant in the flaw. To prevent harming the penetrant material, drying temperature should be kept to less than 71°C. Also, the drying time should be limited to the minimum length necessary to thoroughly dry the component being inspected.

    Developer Quality Control

    The function of the developer is very important in a penetrant inspection. In order to accomplish its functions, a developer must adhere to the part surface and result in a uniform, highly porous layer with many paths for the penetrant to be moved due to capillary action. Developers are either applied wet or dry, but the desired end result is always a uniform, highly porous, surface layer. Since the quality control requirements for each of the developer types is slightly different, they will be covered individually.

    Dry Powder Developer

    A dry powder developer should be checked daily to ensure that it is fluffy and not caked. It should be similar to fresh powdered sugar and not granulated like powdered soap. It should also be relatively free from specks of fluorescent penetrant material from previous inspection. This check is performed by spreading a sample of the developer out and examining it under UV light.

    When using the developer, a light coat is applied by immersing the test component or dusting the surface. After the development time, excessive powder can be removed by gently blowing on the surface with air not exceeding 35 kPa.

    Wet Soluble/Suspendable Developer

    Wet soluble developer must be completely dissolved in the water and wet suspendable developer must be thoroughly mixed prior to application. The concentration of powder in the carrier solution must be controlled in these developers.

    The concentration should be checked at least weekly using a hydrometer to make sure it meets the manufacturer’s specification. To check for contamination, the solution should be examined weekly using both white light and UV light. Some specifications require that a clean aluminum panel be dipped in the developer, dried, and examined for indications of contamination by fluorescent penetrant materials.

    These developers are applied by spraying, flowing or immersing the component. They should never be applied with a brush. Care should be taken to avoid a heavy accumulation of the developer solution in crevices and recesses.

    Solvent Suspendable

    Solvent suspendable developers are typically supplied in sealed aerosol spray cans. Since the developer solution is in a sealed vessel, direct check of the solution is not possible. However, the way that the developer is dispensed must be monitored. The spray developer should produce a fine, even coating on the surface of the part. Make sure the can is well shaken and apply a thin coating to a test article. If the spray produces spatters or an uneven coating, the can should be discarded.

    When applying a solvent suspendable developer, it is up to the inspector to control the thickness of the coating. With a visible penetrant system, the developer coating must be thick enough to provide a white contrasting background but not heavy enough to mask indications. When using a fluorescent penetrant system, a very light coating should be used. The developer should be applied under white light and should appear evenly transparent.

    Development Time

    Parts should be allowed to develop for a minimum of 10 minutes and no more than 2 hours before inspecting.

    Lighting Quality Control

    Proper lighting is of great importance when visually inspecting a surface for a penetrant indication. Obviously, the lighting requirements are different for an inspection conducted using a visible dye penetrant than they are for an inspection conducted using a fluorescent dye penetrant.

    Lighting for Visible Dye Penetrant Inspections

    When using a visible penetrant, the intensity of the white light is of principal importance. Inspections can be conducted using natural lighting or artificial lighting.

    However, since natural daylight changes from time to time, the use of artificial lighting is recommended to get better uniformity. Artificial lighting should be white whenever possible (halogen lamps are most commonly used). The light intensity is required to be 100 foot-candles at the surface being inspected.

    Lighting for Fluorescent Penetrant Inspections

    Fluorescent penetrant dyes are excited by UV light of 365nm wavelength and emit visible light somewhere in the green-yellow range between 520 and 580nm. The source of ultraviolet light is often a mercury arc lamp with a filter. The lamps emit many wavelengths and a filter is used to remove all but the UV and a small amount of visible light between 310 and 410nm. Visible light of wavelengths above 410nm interferes with contrast, and UV emissions below 310nm include some hazardous wavelengths.

    Standards and procedures require verification of filter condition and light intensity. The black light filter should be clean and the light should never be used with a cracked filter. Most UV light must be warmed up prior to use and should be on for at least 15 minutes before beginning an inspection. Since fluorescent brightness is linear with respect to ultraviolet excitation, a change in the intensity of the light (from age or damage) and a change in the distance of the light source from the surface being inspected will have a direct impact on the inspection. For UV lights used in component evaluations, the normally accepted intensity is 1000 µW/cm2 at 38cm distance from the filter face. The required check should be performed when a new bulb is installed, at startup of the inspection cycle, if a change in intensity is noticed, or every eight hours of continuous use.

    When performing a fluorescent penetrant inspection, it is important to keep white light to a minimum as it will significantly reduce the inspector’s ability to detect fluorescent indications. Light levels of less than 2 foot-candles are required by most procedures. When checking black light intensity a reading of the white light produced by the black light may be required to verify white light is being removed by the filter.

    Light Measurement

    Light intensity measurements are made using a radiometer (an instrument that transfers light energy into an electrical current). Some radiometers have the ability to measure both black and white light, while others require a separate sensor for each measurement. Whichever type is used, the sensing area should be clean and free of any materials that could reduce or obstruct light reaching the sensor. Radiometers are

    relatively unstable instruments and readings often change considerable over time. Therefore, they should be calibrated at least every six months.

    System Performance Check

    A system performance check is typically required daily, at the reactivation of a system after maintenance or repairs, or any time the system is suspected of being out of control. System performance checks involve processing a test specimen with known defects to determine if the process will reveal discontinuities of the size required. The specimen must be processed following the same procedure used to process production parts. The ideal specimen is a production item that has natural defects of the minimum acceptable size. As with penetrant inspections in general, results are directly dependent on the skill of the operator and, therefore, each

    operator should process a test specimen.

    There are some universal test specimens that can be used if a standard part is not available. The most commonly used test specimen is the TAM or PSM panel which is used for fluorescent penetrant systems. These panels are usually made of stainless steel that has been chrome plated on one half and surfaced finished on the other half to produce the desired

    roughness. The chrome plated section is impacted from the back side to produce a starburst set of cracks in the chrome. There are five impacted areas with a range of different crack sizes corresponding to the five levels of sensitivity.

    Care of system performance check specimens is critical. Specimens should be handled carefully to avoid damage. They should be cleaned thoroughly between uses and storage in a solvent is generally recommended. Before processing a specimen, it should be inspected under UV light to make sure that it is clean and not already producing an indication.

    Nature of the Defect

    The nature of the defect can have a large effect on sensitivity of a liquid penetrant inspection. Sensitivity is defined as the smallest defect that can be detected with a high degree of reliability. Typically, the crack length at the sample surface is used to define

    size of the defect. However, the crack length alone does not determine whether a flaw will be seen or go undetected. The volume of the defect is likely to be the more important feature. The flaw must be of sufficient volume so that enough penetrant will bleed back out to a size that is detectable by the eye or that will satisfy the dimensional thresholds of fluorescence. The figure shows an example of fluorescent penetrant inspection probability of detection (POD) curve as a function of crack length.

    In general, penetrant testing is more effective at finding:

    Small round defects than small linear defects.Deeper flaws than shallow flaws.Flaws with a narrow opening at the surface than wide open flaws.Flaws on smooth surfaces than on rough surfaces.Flaws with rough fracture surfaces than smooth fracture surfaces.Flaws under tensile or no loading than flaws under compression loading.Health and Safety Precautions

    When proper health and safety precautions are followed, liquid penetrant inspection operations can be completed without harm to inspection personnel. However, there is a number of health and safety related issues that need to be taken in consideration.

    The most common of those are discussed here.

    Chemical Safety

    Whenever chemicals must be handled, certain precautions must be taken. Before working with a chemical of any kind, it is highly recommended that the material safety data sheets (MSDS) be reviewed so that proper chemical safety and hygiene practices can be followed. Some of the penetrant materials are flammable and, therefore, should be used and stored in small quantities. They should only be used in a well ventilated area and ignition sources avoided. Eye protection should always be worn to prevent contact of the chemicals with the eyes. Gloves and other protective clothing should be worn to limit contact with the chemicals.

    Ultraviolet Light Safety

    Ultraviolet (UV) light has wavelengths ranging from 180 to 400 nanometers. These wavelengths place UV light in the invisible part of the electromagnetic spectrum between visible light and X-rays. The most familiar source of UV radiation is the sun and is necessary in small doses for certain chemical processes to occur in the body. However, too much exposure can be harmful to the skin and eyes. The greatest threat with UV light exposure is that the individual is generally unaware that the damage is occurring. There is usually no pain associated with the injury until several hours after the exposure. Skin and eye damage occurs at wavelengths around 320 nm and shorter which is well below the 365 nm wavelength, where penetrants are designed to fluoresce. Therefore, UV lamps sold for use in penetrant testing are almost always filtered to remove the harmful UV wavelengths. The lamps produce radiation at the harmful wavelengths so it is essential that they be used with the proper filter in place and in good condition.


    Full article: /liquid-penetrant-testing/

    Comment Share
  • chris
    chris started the discussion Introduction to MPI / MT in the forum MPI
    5 years ago
    Discussion

    Magnetic Particle Testing

    Magnetic particle testing is a non destructive testing method for detection of surface and near surface discontinuities in ferromagnetic materials.

    Ferromagnetic materials are materials that can be magnetized to a level that will allow the inspection to be effective. They are,

    Iron, Cobalt, Nickel and their magnetic alloys.

    Magnetic particle testing can detect, surface and near surface cracks seams, laps, cold shuts in castings, laminations, lack of fusion near the surface, undercuts, deep scratches and fatigue cracks are indicated. Linear inclusions and porosity at or very near the surface may produce indications.

    The technique uses the principle, that during the magnetization of a ferromagnetic material, magnetic lines of force [ magnetic flux lines ]

    pass through this magnetically conducting medium. If the magnetic flux lines hit an area of different magnetic permeability such as a crack near the surface, a portion of these flux lines gets diverted and leak out above the surface of the material. A magnetic leakage field emerges from the part.

    To show this leakage field, colored finely divided iron particles are sprayed to the area under examination. The leakage field attracts and accumulates some of these iron powder particles and essentially creates a powder caterpillar worm – like visual indication for the human eye. The indication is produced directly on the surface of the part and above the discontinuity.

    There are variations in the way the magnetizing field is applied, but they are all dependant on the above principle.

    All surface and near surface crack like defects which produces a leakage field at the test surface can be detected. No elaborate precleaning is necessary, and surface defects filled with foreign material can be detected.

    Characteristics of a discontinuity that enhances its detection are, Its depth is at right angles to the surface

    Width of the surface opening small, so that the air gap created Is narrow

    Its length at the surface is large with respect to its width

    It is comparatively deep in proportion to the width of its opening.

    In general reliable detection requires that the width – depth – length dimensions of the discontinuities correspond to the ratio 1 : 5 : 10. The lowest detection limits are a 1µm crack width, with a 10 µm depth of cut.

    Optimum crack detection occurs when the magnetic flux lines flow at right – angles to the length of the defect. To form a detectable leakage field, the angle between the field direction and the expected defect’s length shall not be greater than 450 .

    Disadvantages : It can be used only on ferromagnetic materials, has certain application which require large amounts of electrical current and requires the magnetic field to be properly oriented in relation to the discontinuities

    anticipated. Paint coatings and nonmagnetic coverings affect the sensitivity of examination. Demagnetization of the parts following examination may be required. Post cleaning to remove the magnetic particle materials from the test surface is required.

    Detectability of Defects : Detectability depends on formation of a strong leakage field which is dependent on surface opening of the discontinuity and its depth through the part thickness. A shallow surface scratch which may be as wide as it is deep, usually does not produce an indication. If a crack is wide open at the surface, the reluctance of the air gap in the

    crack opening reduces the strength of the leakage field. This, combining with the inability of the particles to bridge the air gap, fails to form an indication. Laps emerge at an acute angle to the surface and a wide air gap is created between its lip and the part surface. The leakage field may be

    quite weak because very little leakage flux takes the path out through the surface lip of the lap to cross this high reluctance gap. If the faces of a crack are tightly forced together under compressive stress, the almost complete absence of an air gap may produce so little leakage field that no particle indication is formed.

    The surface structure of a test piece has a significant influence on the detectability of defects. The surface cutting depth of a defect should be at least twice the associated surface roughness. Defect detectability can be further reduced by false indications arising from magnetic stray fields, accumulation of powder due to surface roughness, part configuration, scratches, scales, slots etc.

    Cases can occur where It is difficult to generate the force required for a positive defect indication.

    Surface irregularities and scratches can give misleading indications. Therefore it is necessary to ensure careful preparation of the surface before magnetic particle testing is undertaken.

    Detectability of Sub Surface Defects : Magnetic particle testing can detect near –

    surface discontinuities of favorable position and adequate size, but the possibility of an indication rapidly decreases when the discontinuity is more than .2 mm below the surface.

    Detection sensitivity increases with increase in magnetic field strength, but with very high field strength magnetic particles will be attracted to defect free areas of the surface as well as to defects. The depth below the surface at which a sub surface defect may be detected is of the order of 3 to 7 mm when direct current magnetization is used, but this will also depend on the size, shape and orientation. Therefore, the deeper the discontinuity lies below the surface, the larger it must be to yield a readable indication and the more difficult the discontinuity is to find by this method.

    Cracks below a non magnetizable surface layer up to 40 µm are detectable.

    Circular and Longitudinal Magnetic fields :

    Circular field : When an electric current is passed through a conductor, a circular magnetic field is produced that is approximately perpendicular to the direction of current flow in the part. This magnetic field has directional properties which depend on the direction in which the current is flowing.

    A simple rule for determining the direction of the magnetic field in and around a conductor, is to grasp the conductor in the right hand with the thumb pointing in the direction of the current flow.

    The fingers then point in the direction taken by the magnetic lines of force in the magnetic field surrounding the conductor. This is known as the right – hand rule.

    [ current flows from Positive terminal to the Negative terminal ] The strength of the magnetic field in and around a magnetic or non magnetic conductor is directly proportional to the strength of the current flowing through it, doubling the current doubles the magnetic field strength.

    Longitudinal fields : When a current carrying conductor is bent into

    a single loop, the circular magnetic flux field surrounding the conductor pass through the loop opening. The magnetic field within the loop has a definite direction, one side of the loop will be a

    north pole while the other side will be a south pole.

    If the conductor is looped a number of times, a coil is formed and each individual turn produces its own associated circular

    magnetic field. These fields add together to form a combined

    stronger longitudinal field around and through the coil.

    The strength of the longitudinal field passing through the interior

    of a coil is proportional to the product of the current, I, in amperes and the number of turns, N, and is expressed as Ampere – Turns. Therefore, the magnetizing force of such a coil can be varied by changing either the current or the number of turns in the coil.

    Coils and yokes produce longitudinal magnetization.

    Vector Fields : When two magnetizing forces are imposed simultaneously in the same part, a vector field is formed which is the resultant direction and strength of the two imposed fields.

    Continuous Method : With this method, the magnetizing current remains “on” during the application of particles, removal of excess particles and performance of the examination. The current may be continious or it may be applied as a series of short shots. The continious method is sensitive and will give indications of fine defects. Soft materials of low retentivity must be tested by this method. Most of the examinations are performed by this method. Residual Method : With this method, a part is magnetized, the field removed and then the magnetic particles applied and inspection carried out. It has the advantage that inspection may be made away from the magnetizing equipment. This method is applicable with parts which retains some magnetic field after the magnetizing field is turned off. This method is less sensitive than continuous method but non relevant indications are reduced and indications are easily interpreted.

    Magnetizing field strength : The strength of the magnetizing field is is a factor affecting sensitivity of examination and recommended magnetizing field strength is 2400 amp / meter or 30 g or .72 tesla

    and above. Test sensitivity also depends on, size, shape and

    general characteristics of the particles used and the nature of the carrier fluid for these particles.

    cont

    Magnetizing Currents : Electric current is mostly used to establish the magnetic field in components during magnetic particle inspection. Alternating current and rectified direct current are the two basic types of current commonly used. Current from single phase 110 volts to three phase 440 volts AC are used to derive the magnetizing current. High magnetizing currents can be obtained by the use of a step – down voltage transformer.

    The type of magnetizing current has significant effect on inspection result.

    Direct Current : Direct current flows continuously in one direction at a constant voltage. A battery is the most common source of direct current. Direct current generates a magnetic field that penetrates deeper into the material and is desirable when performing inspection in search of defects below the surface.

    Alternating Current : high voltage alternating current is the source of electric current power to the industries which is reduced to the required voltage level using a transformer. Alternating current reverses in direction at a rate of 50 or 60 times per second. If alternating current is used, the magnetic field generated within the work piece is largely confined to the area that is close to the material surface. This is known as Skin Effect. Therefore, alternating current is recommended only when the inspection is limited to surface defects. The advantage of using alternating current is that, it is highly sensitive for detection of surface defects such as fatigue cracks and it is easy to demagnetize the work piece after test by gradually reducing the current level or magnetic field to zero.

    Rectified alternating currents : The skin effect limits the use of alternating current, since many inspection applications call for the detection of sub surface defects. Hence, alternating current is converted to one – directional current that is very much like direct current, through the process of rectification.

    Half wave rectified direct current [ HWDC ] : When single phase alternating current is passed through a rectifier, current is allowed to flow in only one direction. The reverse half of each cycle is blocked out, so that a one directional, pulsating direct current is produced. The current rises from zero to a maximum and then returns to zero. No current flows during the time when the reverse cycle is blocked out, hence the amperage is half of the unaltered current.

    HWDC has the penetrating characteristics of direct current. The pulsating nature of HWDC helps formation of magnetic particle indications by vibrating the particles and gives them additional mobility. This added mobility is very important when using dry particles for the inspection. The pulsation is reported to significantly improving detection sensitivity.

    HWDC with dry powder is considered the best combination for subsurface defect detection. For this reason, HWDC is a primary power source for welds and casting inspection. HWDC can also be used with a wet particle suspension to provide good sensitivity for revealing fine surface cracks. Since HWDC will leave a part in a partially magnetized state, it is usually packaged as an AC / HWDC combined unit so that the AC is available for demagnetization. Portable units with up to 3000 amps current is available.

    Full Wave rectified direct current [ FWDC, single phase ] : Full rectification inverts the negative current to positive current rather than blocking it out. This produces a pulsating direct current with no interval between the pulses. Filtering is usually performed to soften the sharp polarity switching in the rectified current. While

    particle mobility is not as good as half wave rectified current due to reduction in pulsation, the depth of the subsurface magnetic field is improved. Reduced particle mobility makes this current less suitable for use with dry particle inspection.

    Three phase full wave rectified direct current [ FWDC, three phase ] : Three phase alternating current is rectified to power high current mobile and stationery magnetizing units, because it has more favorable power transmission and line loading characteristics. This current is normally used in units that provides more than 3000 amperes of current. Three phase power requires a bridge rectifier in each of the three phases. When it is rectified and filtered, the resulting current very closely matches the DC output of a battery. Reduced particle mobility makes this current less suitable for use with dry particle inspection.

    Leakage Field :

    Leakage fields are the basis for magnetic particle examination. A leakage field are the flux lines in the air surrounding a discontinuity in a magnetized part.

    a

    The leakage field which develop at and above the surface of a magnetized material attracts and accumulates iron particles which forms a visible indication on the surface.

    A bar magnet has a pole at each end. They are, a North pole and a south pole. Magnetic lines of force flow through the bar from the south pole to the north pole. Because the lines of force within the bar magnet run the length of the bar, it is said to be longitudinally magnetized.

    If the magnet is cracked at right angle to the length but not broken completely in two, a north and a south pole form at opposite edges of the crack and a leakage field emerge. This leakage field attracts iron particles that outlines the crack.

    Surface Discontinuity : When a part is magnetized such that the direction of the magnetic lines of force is at right angles or nearly right angles to the length of a surface breaking discontinuity, the flux lines are bend into the air above the crack. This bending is caused by the change from high permeability of the magnetic material to the low permeability of air in the gap of the crack. The leakage field spans the narrow air gap throughout the length of the discontinuity.

    When fine iron particles are applied to the surface, the particles are attracted to the poles of this miniature leakage field. The first layer of particles shorten and strengthen the leakage field causing additional particles to be attracted.

    These particles attract more particles until the entire leakage field is filled with chains of tightly held magnetized particles. A surface breaking discontinuity forms a sharply defined indication.

    Near surface Discontinuity : When the discontinuity is near the surface, some of the bent lines of force complete their path within the metal above the discontinuity. Others that complete their bent path in the air form a leakage field that is broader and weaker than the leakage field for a similar surface breaking discontinuity. Thus, the attracted particles which accumulate at the leakage field of a near surface discontinuity are more loosely held. The indication looks wide and fuzzy. For a deep discontinuity, all of the bent lines of force complete their path within the metal above the discontinuity, as a result no leakage field emerges from the part.

    Orientation : The direction of magnetic flux must be at right angles to the length of any discontinuity to produce the strongest indication of that discontinuity.

    When the lines of force are parallel to the length of a

    discontinuity, they follow the metal path along the edges of that discontinuity, rather than span the long direction of the air gap. The result is that no leakage field is created, and in tern no magnetic indication is produced to reveal that discontinuity.

    Induced current magnetization :

    Induction is a magnetizing technique based upon transformer principle. An alternating current is made to flow in a ring- shaped specimen by effectively making it the secondary winding in a transformer set up. Since the specimen is a short circuit single turn, very high current flows through it.

    A coil and a pre-formed laminated core form the primary section and the ring shaped work piece surrounding the core forms a short circuit secondary winding. In accordance with the induction law, the current carrying primary coil induces a circulating current in the secondary, i. e. the work piece. Like a current carrying conductor the circular field associated with this current takes the form of a toroidal magnetic field that encompasses all surface areas on the ring. All circumferential defects in the ring shaped work piece can therefore be detected.

    The magnetizing flux achieved is difficult to calculate because of the unknown efficiency of the transformer coupling, and is usually measured on a test piece with a clamp – round meter, which measures the current flow.

    The choice of magnetizing current for the induced-current method depends on magnetic properties of the part to be inspected.

    Passing an alternating current through a conductor will set up a fluctuating magnetic field as the level of magnetic flux rapidly changes due to the current fluctuation. The alternating induced current in conjunction with the continuous method renders applicable for processing magnetically soft, or less retentive parts.

    Quick Break : For retentive parts, such as for most bearing races or similar parts having high magnetic retentivity, direct current is used for magnetization. The current generates strong magnetic field in the laminated core which passes through the ring. When the current is broken, by a quick break circuitry results in a rapid collapse of the magnetic flux and the generation of a high amperage. Thus the part is residually magnetized with a toroidal field, and subsequent application of magnetic particles will produce indications of circumferentially oriented discontinuities in all surfaces in one operation. This method is used for inspection of hollow circular parts, such as, spacers, rings, discs etc when looking for discontinuities lying in a circumferential surface.

    Transient current : When a bar is longitudinally magnetized, the field at the end of the bar is not truly longitudinal, and does not indicate transverse discontinuities at the ends of the bar. Direct current in the magnetizing coil, suddenly broken, induces a heavy circular current in the extreme outer layers of the metal, which extends to the very ends of the bar. This provides a longitudinal field to indicate transverse discontinuities in such critical areas.

    Current Flow Techniques :

    Direct current flow method may be used when detecting discontinuities at or near the outer surface of the part. The magnetizing current should be applied for a duration of .5 to 2 seconds with a minimum of two shots. In order to indicate the presence of all discontinuities, at least two separate examinations shall be performed on each area. During the second examination, the flux lines shall be directed approximately perpendicular to those used during the first examination. A different technique for magnetization may be required for the second examination.

    Head shot method :

    Direct electrical contact at each end of a component, so that the current passes through the whole part is a rapid and reliable method which is very suitable for the inspection of relatively small solid components. This is done by clamping the ends of the part between the contact heads, generally on a stationary horizontal bench unit that incorporates the source of the current. The contact heads must be constructed so that the surfaces of the part are not damaged, either physically by pressure or structurally by heat from arcing or from high resistance at the points of contact. The current flow is uniform and passes through the entire piece being examined. The circular field thus established around the test part will develop leakage field across defects which lie along the same direction as the connecting line between the contact heads. Strongest indications are produced by discontinuities that are parallel to the direction of current flow. The size and shape of the part will determine whether another magnetic field, perpendicular to the previous direction can be generated in the test part by this method.

    The current to be passed through the part is based on the diameter or cross section area of it. The flux density is inversely proportional to the cross sectional area of the test

    part. To achieve adequate field strength for locating surface and sub surface discontinuities, direct or rectified current is used.

    For round parts, current to be applied is 12 to 31 amps per mm of outer diameter including any hollow portion.

    Alternating current can be used at half of the above current for detection of surface discontinuities only.

    For parts with geometric shapes other than round, the greatest cross sectional diagonal in a plane at right angles to the current flow should determine the inches to be used in current computations.

    For oddly – shaped uniform cross section parts, the following formula may be used to compute the current required for direct current, direct contact magnetization,

    Current in Ampere DC = [ P / 3.14 ] X 1000. Where P is perimeter of cross section.

    Stationary Horizontal Units : The general purpose unit has a built in tank that holds the particle suspension and contains a bath pump, which continuously agitates the bath and supplies the liquid through an adjustable hose to be applied to the test part surface.

    Pneumatically operated contact heads, together with a rigid type coil, provide capabilities of both circular and longitudinal magnetization of the test part. Self contained AC and rectified AC power supplies are available in amperage ratings from 2500 to 10000 Amps. Maximum opening between contact heads varies from 1 to 12 feet. Other options are curtains or hoods and ultraviolet light for examination with fluorescent particles.

    Coil Magnetization :

    Components in which length predominates, can be readily magnetized in the longitudinal direction by an encircling coil.

    For this technique, the magnetic field is produced in the part by wrapping cable around it or placing it within a multi turn fixed coil. Passing current through a coil encircling a section of the test part or encircling the part produces a magnetic field parallel to the axis of the coil. Strongest indications are produced when the length of the discontinuities are at right angles to the axis of the coil. The magnetic field strength of a coil is maximum near the inside wall and zero at the center of the coil.

    Portable magnetizing coils are available that can be plugged directly into a standard electrical outlet. This coils are suitable for bar shaped parts.

    For a bar shaped part, the effective overall distance that can be inspected is 6 to 9 inches on either side of the coil opening. In testing longer parts, either the part must be moved at regular intervals through the coil or the coil must be moved along the length of the part.

    When the cross sectional area of the coil is 10 or more times the cross sectional area of the test part, the required magnetizing current, for object positioned near the inside wall of the coil is,

    I = 45000 D / N L

    For parts positioned at the center of the coil [ larger parts ], I = 43000 R / N {( 6 L / D ) – 5 }

    If the cross sectional area of the coil is less than twice the cross sectional area [ including hollow portions ] of the test part,

    I = 35000 / N {( L / D ) + 2 }

    Where : L = length of the test part

    D = diameter of the test part

    N = number of turns in the coil R = radius of the coil

    These equations hold only if the L / D ratio is between 3 and 15.

    The ease with which a part can be longitudinally magnetized in a coil is significantly related to the length to diameter [ L / D ] ratio of the part. This is due to the demagnetizing effect of the magnetic poles setup at the ends of the part. This demagnetizing effect is very significant for L / D ratios of 3 or less. In such cases, pole pieces of similar cross-sectional area can be attached to both the ends to increase the length of the part and thus improve the L / D ratio.

    Artificial discontinuity standards [ such as QQI ] shall be used to ensure proper current levels along the entire axis of the test length.

    For complex shapes, alternating current is recommended. When testing tubes in conjunction with alternating current, only the outside surface is magnetized. When testing flange-type parts, the magnetic field lines at the plane surfaces enter the material at right

    angles so that the sensitivity to circular cracks on the flange sides is reduced.

    Longitudinal magnetization by Yokes :

    There are two basic types of yokes commonly used for magnetizing purposes. Permanent magnet and Electromagnetic yokes. Both are hand held, compact, light weight and quite mobile. They are used to produce longitudinal magnetization in the test part.

    Permanent Magnet Yoke :

    Permanent magnet is a body which possesses a large amount of magnetic field and exhibits the property of magnetism at all times with little or no loss of strength.

    Permanent magnet yokes usually consists of two individual strong permanent magnets made of highly retentive material such as neodymium iron boron. The two magnets are suitably arranged in hinged arms so that the magnetizing poles at ends are of opposite polarity. The strength of the magnetizing field produced by the permanent magnet yoke is dependent on the initial magnetic charge, magnetic retention properties of the magnets and the distance between the two magnetizing poles. The strength of the field that can be induced in the part is relatively low.

    The yoke and the test part surface form a closed magnetic circuit. The magnetic flux flow in the test part in a direct connection line between the poles thus enabling detection of discontinuities whose linear directions are oriented perpendicular to this line.

    Permanent magnets are used for examinations where a source of electric power is not available or in inflammable and explosive areas where electrical arcing is not permissible. Apart from this, permanent magnets have little to offer as a magnetizing method.

    Permanent magnets can be used as single poles for generating radial field or as pairs to generate a longitudinal field. Inspection area is generally limited to the central region between the poles. The flux is stronger nearer the poles than in the center of the gap.

    Examination for indications near the points of contact is not possible due to the confusing mass of particles that gather at the poles.

    Permanent magnets generate static field and wet particles should be used because dry particles require changing or alternating field to impart mobility.

    When using permanent magnets, the pole pieces need to be in good contact with the test surface and flexible pole pieces are often used to achieve this. Pole spacing should not be less than 3 inches and more than 6 inches.

    The magnetizing force of a permanent magnet yoke shall be tested daily prior to use by determining its lifting power on a steel plate at maximum pole spacing at which it is being used for the examination. The yoke must be able to lift at least 18.1 kg at the examination pole spacing.

    Limitations to use of permanent magnets include the following :

    Large areas or masses cannot be magnetized with enough strength to produce satisfactory crack indications.

    The inability to vary the field strength at will.

    Removal of the magnet from the part is difficult if the magnet is very strong.

    Particles may cling to the magnets, possibly obscuring indications and it is difficult to remove the clinged particles from the legs.

    Electromagnetic Yoke :

    Electromagnets are types of temporary magnets used to produce a temporary magnetic field. They have little or no ability to retain magnetism so that they return to an unmagnetized state when the supply current is switched off.

    Electromagnetic Yokes for magnetic particle examination consist of an U shaped soft iron laminated core with flat ends, in which a coil system generates the magnetic flux when current is flowing.

    Yokes normally have articulated legs which can be moved to accommodate various shapes of test part and ensure good magnetic contact.

    The magnetic flux pass through the soft iron core producing magnetic poles at each end of the core and complete their travel path through the air between these poles. Alternating current yokes provide effective means of part magnetization for detection of surface discontinuities. Half wave rectified current yokes are capable of disclosing surface and sub surface discontinuities.

    Prod Contacts :

    For inspection of large parts, which cannot be tested in a stationary machine and for outdoor examination, magnetization is often done by prod contacts to pass the current directly through the part or through a local portion of it.

    Prod units consist of two hand held electrodes, separate or mounted in a frame and connected to a source of low voltage, high amperage current transformer. When the two electrodes are in contact with the surface of the material and they are energized the current passes through the material to complete the circuit and creates a local distorted circular magnetic field in the material.

    Prods are used in testing weldments on bridges, railroads, pipeline, pressure vessels, tubing, bar stock, forgings, castings, aircraft, ships for detection of cracks.

    This method requires that all mill scale, rust, paint be removed in areas where the prod tips must make electrical contact.

    When using prods, the tips must be placed on the examination surface while the current is ‘ off ‘ and with a spacing between

    3 to 8 inches. 6 inches spacing is generally recommended. Prod spacing, equal to that of the length of the prod is ideal.

    Field strength depends on current, distance between the prods and the section thickness of the part.

    The magnetizing current is selected as follows.

    Direct or rectified current used, shall be 90 – 110 amperes per inch of prod spacing for sections below 3/4 inch thick and

    100 – 125 amperes per inch of prod spacing for section thickness above 3/4 inch. Suitable magnetic fields exist only between and near the prod contact points. The width of the examination zone is 1/4 of prod spacing.

    In order to detect longitudinal and transverse defects in an area or a weld seam, the section must be magnetized in two separate directions at right angles to each other. For longitudinal defects in welds, the prods must be placed adjacent to and on opposite sides of the weld bead on each side of the weld seam so that the current direction to the seam makes an angle of about 20° – 30°. When moving to the next area to be examined the applied magnetic field must overlap the previous examined area by at least 10% so that 100% coverage is assured.

    In prod contact method of examination, the flow of current directly from the prod tips to the test material can cause arcing on the examination surface. Prolonged energizing cycles cause undesirable overheating below the contact points.

    Great care must be taken to avoid burning of the part under the contact points. Burning may be caused by dirty contacts, insufficient contact pressure, or excessive currents. Precautions shall be taken to ensure that the electrical current is not flowing while the prod contacts are applied or removed. Prod tips must be kept clean and dressed to smooth round. If the open circuit voltage of the current source is greater than 25 V, lead, steel, or aluminum tipped prods are recommended to avoid copper deposit on the test surface.

    Sensitivity to defects lying wholly below the surface is greater with this method of magnetization than with any other, especially when half wave rectified current is used in conjunction with dry powder and the continuous method of magnetization.

    The arcing problem, surface preparation for electrical contact, high electrical consumption, heavy weight of the power unit and weight of long prod cables are the disadvantages of this method.

    Prod placement for ground and un-ground weld.

    Electromagnetic Yoke contd :

    When the poles are placed in contact with the test surface and the yoke is energized, the magnetic flux pass through the surface and near surface region of the material in a direct connection line between the poles to complete a local longitudinal magnetic field. Strongest indications are produced with the yoke technique by discontinuities whose length are at right angles or nearly right angles to an imaginary line connecting the two yoke poles.

    The strength of the magnetizing field produced by an electromagnetic yoke is dependent on the magnetic properties of the core, number of ampere – turns, and the distance between the yoke poles.

    In yoke technique, magnetic flux pass from the yoke to the test part through surface contact between the flat ends of the yoke poles and the examination surface. If contact is partial, the flux lines entering the test part are weakened by the high reluctance of the air gap and may be too weak to indicate smaller discontinuities.

    In use, the magnetizing force of a yoke shall be tested by determining its lifting power on a steel plate at maximum pole spacing at which it is being used for the examination. The minimum weight which a yoke must be able to lift at the examination pole spacing is,

    4.5 Kgs for AC yoke.

    18.1 Kgs for DC yoke.

    If a tangetial field meter is used to measure the field strength, the sensor should be positioned midway between the poles and the reading should be between 30 to 60 gauss.

    Magnetic flux pass through both magnetic and non magnetic material. Mill scale or thin paint coating [  .001” magnetic and

    .003” non magnetic ] permits examinations by yoke method.

    During examination, the yoke is to be positioned on the test part with current ‘ off ‘ condition and with full pole faces to test surface contact. When adjustable yoke is used, the examination pole spacing should be between 3 to 8 inches. A pole spacing of 6 inches is generally recommended. In general, discontinuities to be detected should be centrally located in the area between the pole pieces and oriented perpendicular to an imaginary line connecting them.

    The magnetizing field must be applied twice for a complete examination of an area. The fields shall be applied approximately perpendicular to each other. For welds, to detect longitudinal and transverse defects, the magnetic field should be once along the direction of the weld and again across the weld. The weld surface must be ground sufficiently smooth for good contact when the yoke poles are placed in – line on top of the weld material. For as welded surface condition the poles are placed along the same side of the weld and as close as possible to the weld edges.

    With yoke magnetization, burning of the test part is avoided because only the magnetic field is transmitted into it, no current enters the test part.

    Head shot Method :

    The part is fixed between the heads ensuring good electrical contact and the current is passed from end to end. A circular field is developed in and around the part and the discontinuities oriented along the length are indicated.

    If the part contains more than one diameter, then the part is to be tested separately for each diameter. The current applicable for each diameter is applied and the corresponding section is tested. The applicable currents are used in ascending order.

    Central Conductor :

    When current is passed through a hollow cylindrical conductor, the magnetic field on the inner surface is zero. A component with a continuous hole through it can be magnetized without contact by means of a current carrying straight conductor passing through the hole. The examination technique is often used in examination of parts such as pipe connectors, hollow cylinders, gear wheels, springs and large nuts.

    For this technique, a central conductor is used to magnetize the inner surface of the bore with a circumferential magnetic field.

    Defect on the outer surface of a tubular can also be detected if the wall thickness is not too large but there may be a large difference in the magnetic field strength on the two surfaces.

    When the axis of the central conductor is located near the central axis of the test object, 12 to 31 amps current per mm of test object diameter should be applied. The diameter to be used for current computation is the largest distance between two points, 180 degrees apart on the inside circumference.

    Alternating current is to be used only for surface discontinuities on the inside surface of the test object. Where large diameter cylindrical parts are to be examined, the conductor shall be positioned close to the internal surface of the bore and the circumference of the part shall be examined in increments. A

    current of 12 to 31 amps per mm shall apply except that the diameter shall be considered the sum of the diameter of the conductor and twice the wall thickness of the part. The distance along the test object circumference [ ID / OD ] which is effectively magnetized is to be taken 4 times the diameter of the conductor. The parts are the inspected in four quadrants or segments. This provides a greater induced field for a lesser current value.

    Bars or cables, passing through the bore of a cylindrical part, may be used to induce circular magnetization.

    Bars are usually made of copper to reduce heating. If a flexible cable is used, several turns of cable may be passed through the bore and the current reduced in proportion to the number of turns. The magnetic field will increase in proportion to the number of times the central conductor cable pass through the bore.

    The magnetic field adequacy shall be verified using a field indicator.

    The strength of the magnetic field around a magnetic or non magnetic conductor decreases as the distance from the surface of the conductor increases. The amount of decreases is dependent on the conductor material, cross section and type of current.

    Indications produced by central conductor.

    Magnetic Particles :

    Powder blower

    Magnetic particles are finely divided ferromagnetic [ Iron ] material. They must have,

    High Permeability, easily attracted to weak leakage fields. Low retentivity, not attract each other outside magnetic field. Non Toxic, relatively harmless to the user.

    Fine particles are sensitive for surface breaking defects. Coarse particles are superior for sub surface defects. Particles do not act as single unit but clump together to form the indications when magnetized. The particle size should be smaller than the width of opening for detecting surface breaking cracks.

    The two basic types of magnetic particles are,

    Dry Particles, fine or coarse, applied as dry powder.

    Wet particles, fine particles applied as suspended in a liquid.

    Dry Particles : Dry particles are coarse and larger than wet particles. The particles have a range of sizes and shapes and are available in many colors such as yellow, gray, black, brown, red.

    Fluorescent dry particles are also available, but are not in general use mainly because of economic considerations. The color of the particles used for testing is determined by the color of the surface being examined and is selected for maximum contrast.

    Dry particles are superior for detecting flaws lying wholly below the surface because of its higher permeability and irregular shapes.

    Large heavy particles are not likely to be arrested and held by a weak leakage field when they are moving on the part surface.

    Very fine dry particles behave like dust and easily adhere to any damp or slightly oily surface to produce heavy dusty background. Finer particles add mobility and sensitivity for fine surface cracks while larger particles add sensitivity for detection of sub surface defects and counteract the tendency of the finer ones to leave a dusty back ground. Dry particles which are a mixture of coarse and fine particles are mostly preferred.

    Dry powder are primarily used on rough surfaces, such as un- ground welds and castings, threaded parts and for detection of defects below the surface. It does not have the tendency to drift into the roughness of the surface as a wet suspension does. Dry particles with half wave direct current and prods is the best approach when inspecting lack of penetration in thinner welds and hot tears and cracks in castings.

    When used outdoors, breezes can cause the dry powders to blow around. Dry particles are not affected by cold and can be used at low temperatures. They are also heat resistant, and many powders are usable at temperatures up to 6000 F.

    Reclamation and reuse of dry particles is not recommended. Application : Air is used to carry the particles to the examination surface. Dry powder should be applied such that the particles approach the examination surface in a uniform cloud with minimum of motion. In this way the particles reach the leakage field while suspended in air and have three dimensional mobility. This condition can be best achieved when the magnetized surface is vertical or overhead. When particles are applied to a horizontal or sloping surface, they settle directly to the surface and do not have the same degree of mobility. Half wave rectified direct current is recommended with dry particle inspection to impart the required mobility. The magnetizing current must be initiated before the application of the particles to the test surface and shall be terminated after the excess particles have been blown off.

    For Dry particle examination, the test surface must be dry, free from grease and other adhering deposits. The particles themselves must be free from moisture.

    The relative merits of dry particles depend on the skill in application. Dry powder can be applied by small rubber spray bulb, squeeze bottles or specially designed powder blowers. The air stream of these blowers is of low velocity so that a cloud of powder is applied to the test area. These blowers can also deliver a light stream of air for gentle removal of excess powder from the examination surface. Excess dry particles around an indication, can be removed by a regulated air supply, air bulb or gentle blowing while the magnetizing field is present. The air stream should be of sufficient force to remove the excess particles without disturbing those particles that are evidence of indications.

    Precautions shall be taken to prevent inhaling of dry particles.

    Magnetic Particles :

    Wet particles are finer in size [ avg 6 and up to 25 microns ] and are sensitive for detection of surface flaws such as fatigue cracks and other close to surface defects. The particles are applied with a liquid carrier. Particle sizes more than 20 microns settle out of suspension rather rapidly and are left behind as the suspension liquid drains off. Stranded particles often line up and produce false indications. In the case of finer particles, the stranding due to draining away of the liquid occurs much later, giving the particles mobility long enough to reach the leakage fields and accumulate to form the indications.

    Wet particles are commonly used in stationery horizontal units where a recycled bath can be used until contaminated and discarded. They are also used in field operations with portable magnetizing equipments. Care must be taken to agitate the bath constantly to keep the particles suspended.

    The particles are available in colors such as black, brown, dark red, green etc. Black particles are more sensitive. Fluorescent particles are also available where the particles are bonded to a fluorescent chemical which fluoresce brilliant yellow – green or orange – red under ultraviolet illumination. These particles have excellent visibility when illuminated by Ultraviolet light.

    The particles are supplied in the form of a paste, concentrates or powders, that is to be suspended in liquids to produce the coating bath. The liquid is usually a light oil, such as kerosene, or it can be water. Water uses conditioners such as wetting agent and corrosion inhibitors. These conditioners are usually incorporated in the pastes and concentrates. Proper wetting of the test surface shall be determined by a water break test.

    The bath shall be applied either by gently spraying or flowing the suspension over the area to be tested. It is important to apply the suspension liberally and to allow it to flow slowly across the area of examination so that the particles can migrate to the leakage fields freely. The application of suspension must stop before the magnetizing current is switched off, otherwise the indications may be washed away. Weakly held indications on highly finished parts are readily washed away and care must be taken to prevent high velocity of the bath flow over critical areas.

    Some technical experience is needed in applying the suspension properly, but more errors are made by not using correct particle concentration and state of cleanliness in the suspension.

    Settling Test : Mixing wet particles should be as specified in the test procedure or as recommended by the manufacturer. The particle concentration for newly made mixture can be checked in the pear shaped ASTM centrifuge tube. 100 ml of fully agitated suspension is poured into the centrifuge tube and allowed to settle for 30 minutes under undisturbed condition. The amount of powder settled can then be read on the graduated cylindrical part of the tube. The recommended settling volume is from 1.2 to 2.4 ml per 100 ml liquid for non fluorescent and from 0.1 to 0.5 ml in a 100 ml bath sample for fluorescent particles, unless otherwise specified by the manufacturer. For re – circulated suspension, dirt in the bath will also settle and usually shows as a separate layer on top of the particles. If a fluorescent bath is under test, the liquid above the precipitate may fluoresce because of oily contamination or release of the fluorescent coating, and the bath must be discarded.

    For re – circulating type test system, the use of centrifuge settling test for checking the concentration after a number of testing cycles is not reliable because of the contamination of the bath by rust, fine scale, dust particles etc left out by test part, will cause false volume reading. An MTU 3 [ magnetized ring with residual field ] can be used to check the efficiency of the used suspension.

    White Contrast Paint : For non fluorescent particles, an easily removable and quick drying white paint [ .001” to .003” thickness max ] should be applied to the test surface so that a high contrast is obtained between the indications and the background. Contrast paint is best applied by spraying, as this results in a thin, even layer.

    Fluorescent particles provide the highest contrast and visibility and do not require contrast medium.

    Demagnetization :

    After the magnetic particle test, there may be some residual magnetism remaining in the part. The amount of this residual magnetism depends upon the retentivity and the level of the applied magnetizing field strength for the purpose of examination. It is necessary to demagnetize the component if residual magnetism is detected. Residual magnetic field can:

    Affect machining by causing cuttings to cling to the surface.Interfare with nearby magnetic and electric equipments such as a magnetic compass.Can create a condition known as ‘arc blow’ in the welding process. Arc blow may cause the weld arc to wander or filler metal to be repelled from the weld. This condition is especially a problem when an automatic welding machine is used.Magnetism in engine and rotating parts can attract metal particles into bearings and increase wear.

    Removal of residual field may be accomplished in many ways. When steel is heated above its curie temperature, it will become austenitic [ non magnetic state ] and loose its magnetic properties. The curie temperature for a low carbon steel is 7700 C.

    It is often inconvenient to heat a material above its curie temperature to demagnetize, so other methods that returns the material to a nearly demagnetized state is commonly used.

    Residual Field Meter.

    Subjecting the component to a reversing and decreasing continuous magnetic field, will effectively demagnetize the part.

    The most common method of demagnetization uses an energized AC coil through which the part is passed. On large parts, the coil is moved away from the part while the power is still on or the part remains in the coil while the current is gradually reduced to zero. The reducing current can be passed directly through the part on relatively large parts.

    DC that is reversed in polarity by special switching devices and by diminishing the applied current in each reversal, demagnetization can be achieved more thoroughly. This multiple step down reversing and decreasing DC demagnetizer works similarly to the AC step down system. Because of the difficulty in reverse switching of DC, the equipment is much more complicated than for AC and therefore, more expensive. A commonly used frequency is one reversal per second. The reversing DC provides deeper penetration than does AC and thus has advantage in application on thicker parts that are difficult to demagnetize. The reversing

    DC may use a coil or the current can be passed directly through the part.

    It is desirable to start demagnetization using a stronger field than that was used to magnetize the part during the examination.

    Yokes can be used in the AC mode to reduce the magnetism from surface of large components. More than one yokes can be used together to strengthen the demagnetizing field.

    Magnetic particle Inspection with AC has the advantage of not leaving a strong residual field in the part so that, in a sense, it is self demagnetizing. Many stationary horizontal inspection units provides demagnetization feature that slowly reduce the alternating field in a coil in which the component is placed.

    A calibrated field meter, known as Gaussmeter, is often used to verify that the residual field has been removed from the component. When using, it is only necessary to touch the lower edge of the meter to the part and read the pointer position on the dial. These center zero meters are available in many ranges, +/- 10 gauss range is the one most often used for machine shop and tool room work. Since magnetic leakage fields are strongest at an edge or corner of a part, this is the best place to measure the residual field. Industry standards usually require that the residual magnetic field be reduced to less than 3 gauss after completing the inspection. 10 gauss field is less likely to cause problem in welding.

    Demagnetization techniques :

    50 cycle AC coil — small parts up to 2 inch dia.

    50 cycle AC, current flow — relatively large size and retentive parts. Reversing DC coil — suitable for small parts.

    Reversing DC, current flow — best for large parts. Wrapping cable, full length — long parts. [ pipes, bars etc. ]

    AC yoke — small parts, local near surface area of large parts. Prod, reversing DC — local area of large parts by reversing prod position, and reducing current in each step by 20 to 40 amps.

    Field Indicators :

    The applied magnetizing field shall have sufficient strength to produce satisfactory discontinuity indications.

    A reference standard may be used for procedure development and system check. The standard may be an actual test object with known When it is necessary to verify the adequacy of magnetizing field strength, it can be verified by using one or more of the following three methods.

    Pie – shaped field indicator : These are artificial flaws used as a convenient rough check of the adequacy and direction of part magnetization; It is not, however intended as a quantitative indicator of field strength or distribution.

    These indicators are made from low retentivity carbon steel pie sections that are brazed together to form a series of crossing artificial flaws lines as shown.

    In use, the field indicator is positioned on the surface to be examined, such that the copper plated side is opposite to the examination surface.

    A suitable field strength is indicated when a clearly defined line or lines of magnetic particles form across the copper face of the

    indicator when the magnetic particles are applied simultaneously with the magnetizing force.

    When a clearly defined line of particles is not formed, or not formed in the desired direction, the magnetizing technique should be changed or adjusted.

    These indicators are best used with dry particle procedures.

    Artificial flaw shims / QQI : The shim shall be securely attached to the surface to be examined, such that the artificial flaw side of the shim is towards the examination surface.

    A suitable field strength is indicated when a clearly defined line

    ( or lines ) of magnetic particles form (s) across the shim face of the indicator when the magnetic particles are applied simultaneously with the magnetizing force.

    When a clearly defined line of particles is not formed, or not formed in the desired direction, the magnetizing technique should be changed or adjusted.

    Shim – type indicators are best used with wet particle procedures. Tangential field strength Gaussmeters : Hall effect tangential field probe should be used for measuring the peak value of a tangential

    field. A suitable field strength is indicated when the measured field is within the range of 30 to 60 Gauss [ 2400 to 4800 Amp / meter ] while the magnetizing field is applied. These meters are not suitable for measuring field strength for encircling coil magnetization methods.

    The active area of the hall effect probe should not be larger than 5 by 5 mm and the center of the detector should be within 5 mm from the test part surface. The plane of the probe must be approximately perpendicular to the surface of the test part at the location of measurement.

    The meter must be calibrated at least once a year or whenever it has been subjected to a major repair, periodic overhaul or damage.

    Interpretation of indications :

    UV light meter.

    Black ink

    Fluorescent

    Examination under UV light

    Discontinuities on or near the surface are indicated by retention of the particle patterns. Localized surface irregularities due to machining marks, grinding marks, weld ripples or other surface conditions may produce non relevant or false indications. Broad areas of particle accumulation, which might mask indications from discontinuities, are prohibited, and such areas shall be cleaned and re-examined.

    Measuring light intensity : For color contrast particles, the examination must be performed under adequate visible light and the intensity shall be at least 500 Lux on the examination surface when measured with a suitable calibrated Lux meter.

    Fluorescent indications shall be viewed in a darkened area using ultraviolet light, called black light. The black light shall be allowed to warm up for a minimum of 5 minutes before the light intensity is measured with a calibrated black light meter. A minimum of 1000 W / cm2 illumination is required on the examination surface. The distance of measurement between the lamp and the detector shall be minimum

    6 inches. The background white light illumination shall not exceed

    20 Lux.

    Dark adaptation : When using florescent materials, the examiner shall be in the darkened area for at least 5 minutes to enable his eyes to adapt to dark viewing. The examiners shall not wear photo sensitive lenses during examination.

    Interpretation of indications 2 :

    Evaluation : The evaluation for indications shall be performed with the current ‘ off ‘ condition, unless the patterns of the indications do not change due to overhead or vertical position of the examination surface.

    All indications shall be evaluated according to the acceptance criteria specified in the written procedure.

    The shape, sharpness of outline, width and the height of particle buildup are the principle features by which discontinuities can be identified and distinguished from one another.

    Surface discontinuities produce indications that are sharp and well defined. Sub surface discontinuities produce indications that are broad and fuzzy. The deeper the discontinuity the lesser the definition of the indication.

    When unusual indications are produced, it may be necessary to establish identity by correlating the results with other examination methods.

    Surface cracks : powder indications are elongated, sharply defined, tightly held and usually built up heavily with powder.

    Seams : are closed tight, shallow longitudinal cracks, produce lighter indications.

    Sub surface cracks : indications are elongated, the deeper the crack the wider and fuzzier the built up of the indication

    Crater Cracks : These are recognized by their patterns which are small and occur at the terminal point of the weld. They may be a single line in almost any direction multiple or star shaped.

    Undercut : An indication produced at weld edges, adheres less strongly than the indications obtained by lack of fusion. Undercut can be detected by visual examination

    Incomplete fusion near the surface : Accumulation of powder will generally be pronounced and the edge of the weld will be seen.

    The nearer the discontinuity is to the surface the sharper the pattern will be.

    Inclusion and Pore at surface : Forms light elongated or round indication.

    False indications : are the indications in which the particles are held by gravity or surface roughness. No magnetic or leakage field is involved in formation of these indications. Magnetic particles can settle in shallow grooves, scratches, and give the appearance of a crack.

    Non Relevant indications : these are true indications produced by leakage fields. However, the conditions causing them are present by design or accident or other features and have no relation to a discontinuity that is considered to be a defect.

    If the magnetization is too high, magnetic particle build up can occur at edges or notches. If a magnetized specimen surface is rubbed with a sharp corner of another magnetized material, a track can be formed which attracts magnetic particles. The indications are fuzzy or intermittent and broad caused by loosely held particles and will not appear after demagnetization. This is known as magnetic writing and is usually the result of accidental abrasion.

    Non relevant indications can be caused by, excessive magnetizing current, abrupt change in section thickness, flow lines in forgings, corners, permeability or hardness difference, brazed joint in magnetic material, magnetic to non magnetic material weld, drilled holes, keyways, slots near the surface.

    Acceptance standard for welds : ASME Sec VIII Appendix –

    relevant indications : indications with major dimensions greater than 1 / 16 in. [ 1.6 mm ].linear indications : an indication having a length greater than three

    times the width.

    rounded indications : an indication of circular or elliptical shape with

    the length equal to or less than three times the width.

    An indication in excess of the limits specified below is not acceptable :

    Relevant linear indications;Relevant rounded indications greater than 3 / 16 in. [ 4.8 mm ]Four or more relevant rounded indications in a line separated by 1 / 16 in. (1.6 mm) or less [ edge – to – edge ].


    Full article: /introduction-to-magnetic-particle-testing/

    Comment Share
  • chris
    chris started the discussion How to become a Rope Access Technician in the forum Rope Access
    5 years ago
    Discussion

    Rope Access Certification

    A career in rope access offers many different opportunities. It’s a great career for those with a head for heights and those who love to work in the great outdoors often in remote locations.

    The role encompasses a wide range of different skills and duties vary significantly depending on your experience and qualifications. For example, rope access incorporates jobs such as welding, plating, blare repair, painting and repair work, as well as inspection jobs such as coating surveys, safety inspection and quality control. All of these roles can be on land or offshore based but with one thing in common, they’re classified as being highly skilled!

    If you’re considering becoming a rope access technician offshore, you’ve certainly landed in the right place. We’ve created a helpful guide outlining everything you need to know about kick starting your career.

    Getting the right qualifications

    First and foremost, you should be aware that any career in rope access requires the correct qualifications. There are three main levels of qualifications in the IRATA training and certification scheme. These qualifications will provide you with an IRATA license so you can become a fully-fledged industrial rope access technician.

    And, because you can progress through different levels, including a IRATA level 1 refresher course, IRATA level 2 training, IRATA level 3 training, and IRATA Rope Access Manager Rope Access Safety Supervisor training (RAMRASS), you can progress at a pace that works for you but typically serving at least 12 months between each grade and documenting at least 1000 rope hours.

    Rope Access Certification

    Each level reflects your skillset and experience. For example, at level one, you will work as an operator and use existing rigging, providing you are under the supervision of a person qualified at level three.

    Once you’ve passed this qualification, you can then progress to level two, where you will learn how to set up rigging and even carry out colleague rescues. Finally, once you’ve completed rope access level 2, you can then progress to rope access level 3 where you will allocate jobs and supervise personnel onsite or within a team.

    So, what does training entail?

    All rope access training will provide you with the practical skills you need to progress in a career. You will learn through participating in practical exercises that will provide you with the skills, knowledge and expertise you need to gain a first-hand insight into the job role and what life is like working at height.

    You will also be assessed at the end of your course on your technique and you will also be asked a number of different questions on manoeuvres.

    What will you be assessed on during your rope access level 1?

    If you are ready to kick start your career in rope access, this is what you can expect to cover during your rope access level 1! This should give you an idea of whether this is the right career path for you.

    The rope access level 1 course covers:

    · Safe working systems and assessing of risk.

    · Safe practices.

    · Anchor systems.

    · Understanding of how IRATA works.

    · Personal protective equipment and usage.

    · Basic rescues and correct care.

    · Rope system rigging.

    · Fitting of equipment.

    · Manoeuvres, including; descent, ascent, rope changing, work seats, deviation, edge transitions and rope protection.

    · Work position systems and fall arrest.

    This will give you the skills you need to embark on your new career.

    How Much Does a Rope Access Technician Earn?

    Learning the Ropes – how to stay safe when working at height
    Rope Access is an industry that requires technicians to work safely at height or access difficult to reach places, fast. Requiring extensive training, rope access encompasses a wide range of different techniques that can be adapted to meet the needs of industrial, construction and maintenance requirements, across a diverse range of different sectors and industries.
    And, if you are thinking about becoming as fully-fledged rope access technician, it’s highly likely that safety may have already crossed your mind! The good news is, this is an industry that takes safety incredibly seriously and, throughout your industrial rope access training, as a IRATA level 1, IRATA level 2 and IRATA level 3, you will cover all safety measures and precautions imaginable to ensure you’re always on top of your game at height.
    So, what is involved in rope access safety?
    A rope access technician’s job involves everything from rigging off a roof, through to abseiling the leg of an oil rig or wind turbine jacket, above water. The role is definitely not for the faint hearted, especially if you are afraid of heights, as it will be your job to safely reach inaccessible places that are a far cry from the everyday routine maintenance of buildings or other structures.
    In order to reach these heights safely and securely, you will usually be asked to enter through a roof hatch or from another rigging area where a rope access specialist can rig the dual lines from.
    The ‘Working at Height Regulations 2005’ also state that: “every employer shall ensure that work at height is properly planned; appropriately supervised, and carried out in a manner which is so far as is reasonably practicable safe”.
    With this in mind, if you are looking to embark on a career in rope access, it is essential that you are trained to the highest standard and that you are provided with suitable equipment, protection and fully understand all emergency evacuation and rescue procedures you may encounter.
    IRATA approved rope access
    Rope access workers are highly trained professionals and in order to acquire the skills, knowledge and experience you need to carry out your role safely and effectively, you will need to undergo IRATA training at an IRATA approved training centre.
    The vast majority of technicians and companies will register with IRATA (Industrial Rope Access Trade Association) because IRATA is the sole global trade association in the work at height sector and is widely recognised in all corners of the world.Is a career in rope access for me?
    Like any career, a job in rope access isn’t for everyone and, if you’re considering becoming a professional, fully fledged rope access technician, it’s important that you fully understand what the role entails so you can decide whether or not it’s the best career option for you.
    After all, the role of a rope access technician incorporates a wide range of different duties and different levels of qualifications are required depending on the job role you want. And of course, working at extreme heights definitely isn’t for everyone and it’s certainly not your average environment.
    To help you decide whether this is the right career move for you, we’ve weighed up the pros and cons of becoming a rope access technician.
    Pros and cons
    As with any job there are pros and cons to life as a rope access technician and although the job is financially lucrative and exciting, hours can be long and it can often mean a lot of time away from home, and outside the UK.
    Let’s take a look at some of the pros and cons of a career in rope access.
    Location
    A lot of rope access technicians chose their career due to the opportunity to experience new places, often in all corners of the world. Travel comes hand in hand with this career and although some locations can seem glamorous, many are off the beaten track or require remote working.
    Rates and salaries
    Rates and salaries vary significantly depending on your industry experience, level of expertise, duties and the company that you work for. All technicians start at Level 1 and work their way up! At the top of your career as a level 3 rope access technician, you could be earning as much as £78,000! Dangle is of course an Living Wage Scotland member also.

    Rope Access Courses
    If you do decide that this career is right for you, you will then need to get the right qualification and skills to kick start your journey as a professional rope access technician, in a field of interest, like blade repair or industrial painting etc. Qualification involves completing dedicated working at height training courses via IRATA, the governing body of the rope access industry.
    There are three different rope access technician courses, IRATA Level 1, IRATA Level 2 and IRATA Level 3. All have been created to allow rope access technicians with the training, skills, and knowledge required to carry out manoeuvres and rescue procedures in line with stringent industry and safety requirements required for the level you wish to be assessed at.
    What are the different types of jobs?
    When it comes to exploring job roles in Rope Access, there are many different opportunities. An exciting career that requires skill and mandatory qualifications, you will be surprised at the varied job roles that involve rope access.
    So, what exactly does a job look like?
    To embark on any rope access role, extensive training is required and all rope access technicians are expected to gain a variety of skill sets and qualifications.
    The vast majority of technicians and companies will register with IRATA, which is the world renowned Industrial Rope Access Trade Association. And, as IRATA is the sole global trade association in the work at height sector, it leads the way when it comes to providing the highest standard of training.
    These qualifications are gained by completing standardised training courses at varying levels (IRATA Level 1, IRATA Level 2, IRATA Level 3) which cover everything from rope access manoeuvres and equipment inspections right through to rescue procedures and safety regulations.
    Let’s take a look at some of the fields of work you could enter once you have your qualifications:
    Offshore industries
    Rope access job roles are commonly associated with many offshore industries, and due to the stringent safety requirements and limited working space, offshore rope access technicians are required to undergo extensive training, including but not limited to Sea Survivial, Firefighting, Manual Handling, First Aid, Helicopter Underwater escape training etc.
    There is always a high demand for rope access work on oil rigs and offshore platforms and duties include everything from inspection and maintenance jobs right through to Construction and commissioning jobs.
    Geotechnical industries
    If you’re looking for adventure in your job, rope access in Geotechnical industries is definitely for you! Typically positioned up on cliffs, along steep roadsides, deep within caves or other unreachable natural structures, rope access work in this industry will generally take you to all corners of the world. Main roles include stabilising structures, preventing rock falls and helping to prevent mass erosion.

    Built structures
    You will also find that there are a lot of exciting job opportunities on land too involving working on man-made structures such as bridges, radio masts, bridges or dams. These opportunities can also take you all over the world. Tasks include cleaning, updating and the repair of a variety of different structures.
    Energy industries
    Again, this is a field of work that has become synonymous with rope access jobs on wind farms, power stations and utility poles. Rope access technicians play a crucial role in the surveillance and safe upkeep of all aspects of energy industries as a core key worker your service here will be highly valued in keeping the planet moving.

    Earning potential of rope access technician?
    For those considering a career in Rope Access, one of the first questions often asked is: “How much does a rope access technician earn?”
    But truth is, salaries vary significantly across the industry, depending on experience, qualifications, location and the level of risk involved in the job you are doing. Rope access is a highly skilled career and encompasses a wide range of different duties including a number of different maintenance and inspection jobs.
    For example, maintenance jobs include rust removal, painting, repair work and welding whereas inspection jobs include quality control, safety inspection and coating surveys.
    So, how much does a rope access technician earn?
    The average Rope Access Technician salary in United Kingdom is £54,600 per year, however this may change slightly depending on the company you work for and the location. The vast majority of entry level positions start at £31,200 per year, with that rising as you gain in experience.
    In the UK, an experienced Level 3 Rope Access Technician can expect to earn as much as £78,000 per year.

    Different training levels
    To reach the top of your game and hit a £78,000 salary, you will have to undergo an minimum of three levels of training – Rope Access Level 1, Rope Access Level 2 and Rope Access Level 3.
    These courses are designed to provide aspiring rope access technicians with the training, skills, and knowledge required to carry out manoeuvres and rescue procedures in line with stringent industry and safety requirements often referred to as ICOP and TACS. Each course varies based on the level of skill needed to progress in your career and all courses run for five days, with an assessment at the end.
    Across the industry, you will find that rope access technicians that have vast experience, additional skills and top qualifications will earn far more than other colleagues working in the trade. With this in mind, it’s certainly worthwhile getting the qualifications you need.
    There’s also a high amount of overtime available, which is ideal for boosting your wage, although be prepared to work in excess of 12 hours a day.
    How do I get IRATA certified?
    If you are looking to get IRATA certified, you will have to complete a four/five-day minimum rope access training course from an IRATA Training Member Company and managed by an IRATA Level three Instructor.

    About Dangle
    Here at Dangle, we provide a variety of professional comprehensive inspection, access, coatings, and composite (IACC) industrial services. These professional services are available to both the private and public sectors as well.
    We offer high-quality proven solutions that will help reduce maintenance costs in both the long and short-term. We are based in Dundee, Scotland but also have an office based in Preston, England as well.

    /how-to-become-a-rope-access-technician/



    Comment Share
  • chris
    chris started the discussion Advanced Analysis Software Maximizes OmniScan™ Users’ Weld Analysis Capabilities in the forum Phased Array
    5 years ago
    Discussion

    Olympus’ release of its WeldSight™ companion PC software for the OmniScan™ X3 phased array flaw detector provides inspectors with powerful tools to push the boundaries of flaw characterization and sizing. Compatible with conventional UT, phased array (PA) and time-of-flight diffraction (TOFD) acquired data, the software enables inspectors to perform thorough post-inspection analyses that comply with strict validation requirements of international standards.

    Optimized Analysis Tools for Complex Weld Inspections
    Experienced PAUT inspectors can perform advanced validation of indications using the software’s weld analysis tools. Inspectors will save time with powerful screening capabilities that cut down the need for cross-validation. They can characterize and orient flaws faster, even in complex geometries, by merging distinct scan files and using multiple view options to examine the weld in detail from all sides.

    WeldSight software is also equipped with an innovative geometry-based weld gate that generates a C-scan using data from inside the weld only. This as well as other exclusive post-inspection functionalities give inspectors the ability to fully exploit and fine-tune their OmniScan X3 acquired data to accurately pinpoint the areas of interest and precisely size and characterize flaws.

    Flexible and Customizable
    To enable inspectors to comply with the requirements of a specific procedure, application or code, the software’s scan data displays can be dragged and dropped to create a customized layout. Acquisition data integrity can also be validated and improved with the missing data statistics, editable gates, and encoder recalibration tools.

    About Olympus

    Olympus is passionate about the solutions it creates for the medical, life sciences, and industrial equipment industries, as well as cameras and audio products. For more than 100 years, Olympus has focused on making people’s lives healthier, safer and more fulfilling by helping detect, prevent, and treat disease, furthering scientific research, ensuring public safety, and capturing images of the world.

    Olympus’ Industrial Solutions range from industrial microscopes and videoscopes to nondestructive testing technology and X-ray analyzers. These products are widely used for quality control, inspection, and measurement applications. Serving customers in fields such as manufacturing, maintenance, and environment and natural resources, Olympus technology contributes to the quality of products and adds to the safety of industrial infrastructure and facilities. For more information, visit Olympus-IMS.com.

    /advanced-analysis-software-paut/

    👍2
    Comment Share
  • chris
    chris started the discussion DUTIES OF WELDING INSPECTOR in the forum Visual Welding Inspection
    5 years ago
    Discussion

    DUTIES OF WELDING INSPECTOR

    🕵️ Welding inspector is the person responsible for supervising all activities and duties and following up on all welding workers to ensure everything goes well Duties Of Welding Inspector's main functions are his responsibility to monitor all aspects and procedures of welding operations and have been classified by experts especially TWI - CSWIP and the American Association of AWS - CWI The following: ⤵️

    1. pre welding

    2. stage while doing welding

    3. stage after finishing welding

    The goal of determining liability is to ensure that the welding is finalized according to the specifications and requirements of the code or criteria specified or according to the specifications of the project and the task is often pertaining to the visual inspection and should therefore be The inspector is great at assessing defects and results in general according to international standards and project related specifications. Here is a detailed explanation of all the tasks required of the welding inspector to perform.

    🎯 First: Inspector duties and duties before welding

    Welding inspector should review a list of all variables and operations before welding and it is not limited to the specifications of WPS welding so WPS can only be fully realized if equipment is available and other documents are available as well Optimization and inspection levels vary by consequential to the requirements of a certain code or standard and not limited to raising awareness of the team or helping solve problems but most often it is as follows :- ⤵️

    ▪️ Documents and Documents

    Confirming the latest versions of both geometric graphics, standards, and technical specifications.

    Check and correct the welding procedures qualified welding procedures and work on putting them in the right place and make sure there is the name of the welding process to be used.

    Making sure the welders and technicians are fully qualified to do this with the WPS

    Working on making sure there are special instructions documents on non-destructive testing and I'm already in the right place.

    Ensuring interpass welding or if necessary instructions on PWHT

    Making sure temperatures are set, temps are fixed, temperatures are measuring methods and so on.

    ▪️ Welding equipment and tools

    Making sure the welding machines are functional while checking the history and health of the calibration machine. There is usually some equipment that doesn't have calibration screens, so it needs to be confirmed.

    Making sure all attached equipment like ovens, cables, crude flame in English ovens, quivers, remote controls, torches, cables works properly and has no faults

    If the subject needs PWHT, make sure thermal processing equipment is in place and it works properly and calibration is intact

    ▪️ Basic materials and consumer raw materials

    Ensure and verify that the correct material will be used and in an acceptable condition according to the specifications and criteria related to the project

    Certificates of production of materials in English, material certificates, indicate the correct numbers and grades that correspond to the nature of work, heat, etc.

    Verify other consumables such as welding wires, coated wires, or gas types used and properly prepared to the manufacturer's specifications.

    Check any other consumer certificates and make sure they match work specifications

    ▪️ security, safety and environment

    Verified and committed to ensuring necessary precautions are taken on work permits and all required equipment for safety and security are in place

    Making sure all electrical equipment works correctly and not susceptible to electrical diamonds

    Making sure ventilation is good and enough in the workplace

    Ensuring security and personal protective equipment is properly and properly used

    ▪️ set up and fitting welding links

    Making sure the welding and joint links are set up according to the established procedures and using a certified style like flame cut, ground, machined, etc

    Making sure the sizes of welding and joint links are the right size in terms of angles groove angles, groove radius, root face, etc. All the root gaps and alignment are done according to proper procedures and this point has been adequately explained in welding codes.

    Ensuring the application of heating operations is attached to the required specifications and according to WPS welding procedures

    🎯 Second: liability, duties and functions of welding inspector (during or during the welding process)

    Welding inspector must monitor all aspects of actual welding process to make sure operations and inputs are properly applied and that welding is formed according to WPS welding procedure document and in fact it would be negligent to take all preparations and surveillance for pre and after tasks This simply doesn't comply with the accuracy of the procedure and many welding operations failed because the operator doesn't have a vision of the scale of the process so a detrimental effect on the mechanical properties of welded links so it's one of the inspections and welding inspectors is to monitor all Participants while forming welding may have to carry out previous tasks including the following tasks:

    Monitoring and recording of welding dusty like power of power run-out lengths and measuring voltage

    Monitoring and recording environmental and climate conditions such as (rain - wind - snow - and other harmful weather factors) that can affect the form of final welding.

    Monitoring and maintaining regular temperatures including pre-heat temperatures.

    Ensuring the interpass is properly cleaned

    Check and monitor all interpass temperatures and maintain the required temperature

    Checking and monitoring all Root-run runs with heat monitoring

    🎯 Third: Duties and responsibility of welding inspector (post-welding stage)

    Once each welding is completed, one of the inspector's responsibilities is to carry out the required inspections and tests by qualified staff and technicians to work while meeting the relevant code and criteria requirements and the most important of these tasks as follows.

    🔸 Ensuring PWHT thermal treatment is performed and applied by qualified people using proper procedures and equipment properly in some cases such as hydrogen crack requires thermal treatment before and after NDE non-destructive tests.

    🔸 Making sure NDT tests have been conducted and have been reviewed by welding inspector.

    🔸 Performing the optical inspection of completed welding, measurement, and related defects assessed according to the special criteria and specifications of the process

    🔸 keeping welding records with welding type and number

    🔸 Ensuring other tests such as pressure testing for pipelines, pipes, and pressure vessels after thermal treatment with results being recorded.

    🔸 Preparing necessary reports for the process.

    🔸 Taking all documents and documents related to the process and delivering them to the consultative office in charge of the project

    🎯 Fourth: Repairs after welding stage

    In case of a glitch or defects arise during inspections, there are three main options for a welding inspector. This actually depends on the size and severity of the flaws in welding, it can can cancel the welded item or give the defect permission to stay or Decides to fix the defect and cut the weld.

    Allowing and privileges

    This is the case where welding flaws are not very harmful and have no direct effects on welded elements so the welding inspector allows the defect to stay in place, and in some cases circumstances may require the circumstances to give the defect this privilege with a situation Certain restrictions on service and operation or other restrictions such as required to fix this defect later is more appropriate.

    Repair and adjustment

    In some cases welding process can require repair using different welding process, different consumables or a total change in WPS original wages and a number of repairs to these defects may be restricted depending on the material used so it should be close Repair procedure is written in detail what is required in the repair and adjustments process.

    In fact, the simplest way of adjustments and repairs is for inspector to monitor the repair process before, during and after welding and this gives greater guarantee that the repair will be done properly and that the welding will fit for the established action.

    🎯 V: More information about welding inspector's duties 🎯

    At the end of this article on the duties and responsibilities of the welding inspector, I will quote you these sayings about the welding inspector from the TWI CSWIP book who said it is the duty of the welding inspector to ensure that all welding wages are implemented according to the established specifications and must

    Monitoring to monitor all welding related procedures at all stages of production

    Registration for all process-related checkpoints to ensure quality of welding production including final reports showing all defects identified.

    Reviews are comparing all recorded information with standards and other standard specifications that relate to welding and working on applying.

    I can also add some information about risks from gases during welding and thermal cutting since in doing these jobs, gas hazard is generated, usually gas is generated based on the process used and the operating mechanisms are therefore formed and established Dangerous in some operations and we use protective gas or shielding from atmospheric factors during molten welding or during cutting so gas is burned during consumption. In fact, there are many gases used within the scope of monitoring hazardous substances on health regulations as reported in COSH of 2002 which require some precautions during exposure and knowledge of the limits of gas exposure during welding operations and values are given in directive notes by the administration HSE health and safety and updated annually.

    Gas exposure can also be measured according to the methodologies mentioned in BS EN ISO 10882-2 for health, safety and environment during welding and similar operations by sampling airborne gas particles in the breathing area For the surroundings during operations, measurement is used to verify compliance with regulations and determine the need for surveillance with practical control systems to provide information about gas concentration and their health impacts and limit exposure to them besides welding and fumes exposure evaluation Other similar operations

    Comment Share
Sponsor of NDT InspectSponsors keep NDT Inspect free for its members