pgr380 started the discussion Submerged Coatings DFT Inspection4 months ago
Coating: Modified Polyamine Epoxy
Application: Submerged service; wastewater treatment plant clarifiers
Currently inspecting new submerged coating (Tnemec 66 and 141) for dry film thickness. Specification calls for 4-6 mils primer and 10-15 mils top coat. So total DFT requirement is 14-21 mils. Some of the coating is applied to the inside and outside of a 10 ft diameter drum (open on top and bottom). The remainder is applied to angle iron fabricated into a truss like structure 80 ft long.
There is no spec for testing DFT's other than the implication that any DFT reading cannot be less than 14 mils which is probably unreasonable. However, applying SSPC PA2 (5 avg readings over 100 sq ft) to the drum seems inadequate to me for submerged coatings and since we've had quality control problems with the painter. Any advice on how to tighten up PA2 to catch areas of low DFT's?
Also, PA2 doesn't seem practical when testing small surface areas (such as angle iron). I've proposed taking 4 or 5 readings for each length along each face of each angle (generally 6-8 ft) and averaging that. Any thoughts?
Thanks -
pgr380 became a registered member4 months ago
50 groups across every method and sector
Popular NDT groups

NDTGeneral NDT Group794 membersWelcome to NDT Inspect's general NDT discussion group, a place for…Open group
NDTUltrasonic Testing (UT)739 membersWelcome to NDT Inspect's ultrasonic testing (UT) group, a place for…Open group
SectorsOil and Gas Sector715 membersGroup deducated to Oil & Gas Sector.Open group
Codes and StandardsCodes and Standards684 membersWelcome to NDT Inspect's NDT and inspection codes and standards group, a place…Open group
SectorsAerospace Sector680 membersAerospaceOpen group
NDTPhased Array Ultrasonics (PAUT)662 membersWelcome to NDT Inspect's phased array ultrasonics (PAUT) group, a place for…Open group
SectorsNuclear Sector652 membersNuclearOpen group
SectorsChemical Sector645 membersGeneral group for chemical sectorOpen group
SectorsPower Sector641 membersGeneral group for power sectorOpen group
NDTDye Penetrant Inspection (PT) (DPI)634 membersWelcome to NDT Inspect's dye penetrant testing group, a place for…Open group
955 discussions · 372 answers
Latest forum discussions
RadiographyFILM RADIOGRAPHY Optical Density Vs CR Radiographywilliam · 2 replies · 2 hours agoHi all how compare conventional film radiography optical density vs CR radiography SNR/Gray value please…Read discussion
Failure MechanismsAmine crackingkenton · 1 reply · 1 day agoAmine cracking can occur in carbon steel pipelines, which are commonly used in the oil and gas industry. The…Read discussion
NDTRegarding NDT Level IIIRahul Jeganathan · 1 reply · 1 day agoI am planning to pursue NDT Level 3.I have 8 Years of experience in NDT & Project Handling, I hold PCN…Read discussionAcoustic EmissionAcoustic Emission testing instrumentsleo · 2 replies · 1 day agoWe are searching for a Acoustic emission testing equipment manufacturer for a project in Sri Lanka. Please…Read discussion
Coating InspectionSubmerged Coatings DFT Inspectionpgr380 · 0 replies · 1 day agoCoating: Modified Polyamine EpoxyApplication: Submerged service; wastewater treatment plant…Read discussion
Quality ControlVietnam Supplier Quality: Control the Process, Not Only the Final ShipmentyVIS_Global_82756 · 0 replies · 17 days agoVietnam Supplier Quality: Control the Process, Not Only the Final ShipmentBy VIS Global Editorial…Read discussion
Chemical SectorLooking for Quality Cocamide DEA (CDEA) as a Foam Booster & Thickener?HooChemtec · 0 replies · 6 months agoHello everyone, I’d like to introduce Cocamide DEA (CDEA), a versatile surfactant widely used in personal…Read discussion
Chemical SectorSeeking Advice on Cooling Water Treatment ProgramsHooChemtec · 0 replies · 6 months agoHi everyone, I'm looking for practical advice on industrial cooling water treatment. We run an open…Read discussion
Radiographysensitivity calculation in RTwilliam · 3 replies · 7 months agoDear Experts, we have a radiography film of 2 inch 5.54 mm thickness weld, technique is DWDI. Now for…Read discussion
Digital RadiographyNeed for RT2 inspector in DRyassine-ab · 1 reply · 8 months agoHello community,I am from SGS Morocco, in charge of NDT aero development.I have an urgent need of Cofrend…Read discussion