Inspection technician working on pipework at an industrial plant

What’s new

The NDT community, live

Updates, photos, documents and polls from members, groups and companies — join the conversation.

The NDT Inspect community

What’s new

  • 37 posts this week
  • 1 online now
  • 5,507 members

What’s new on NDT Inspect

Latest NDT & inspection industry news, jobs and community updates

Live updates from the NDT Inspect community: new NDT job vacancies, product launches from the virtual exhibition, forum discussions and member activity across ultrasonic, radiographic, phased array and every other inspection method. Join free to post and follow.

Share an update with 5,507 NDT professionals…Join free

Members post updates, comment, react and follow the companies they work with. Already a member? Sign in

  • Mark Gilmour
    Mark Gilmour posted an update in the group Radiography
    1 month ago
    Update

    A visible IQI wire tells you something important, but not everything.

    In a simplified wire-to-thickness example, a 0.20 mm IQI wire is visible through 10 mm of material.

    What percentage ratio is that?

    More importantly, does it guarantee that every 0.20 mm crack would also be detected?

    My explanation is below. This is a principle question, not a complete code-compliance assessment.

    Answer: 2%.

    (0.20 ÷ 10) × 100 = 2%

    But no, that does not guarantee detection of every crack of a comparable size. An IQI is an image-quality reference, not a universal minimum-defect-size guarantee.

    Crack orientation, the radiation path through the discontinuity and image contrast affect detectability. The applicable technique, IQI selection and acceptance requirements still need to be met.

    More revision questions and explanations in NDT Pro Study Plus. Free preview:
    ndt-pro-study-plus.pplx.app
    Explore the free preview of NDT Pro Study Plus, my independent revision app. The full library is subscription-based.

    Comment Share
  • Mark Gilmour
    Mark Gilmour joined the group Radiography
    1 month ago
    Community
    Comment Share
  • Mark Gilmour
    Mark Gilmour joined the group Ultrasonic Testing (UT)
    1 month ago
    Community
    Comment Share
  • B. Rajesh Kumar
    B. Rajesh Kumar joined as NDT Professional
    1 month ago
    Community
    Comment Share
  • Jim Markatos
    Jim Markatos joined as Inspection Engineer
    1 month ago
    Community
    Comment Share
  • Vivek Rohra
    Vivek Rohra added a company listing, AIT Products, LLC (Advanced Inspection Technologies)
    1 month ago
    Company
    Company listingAIT Products, LLC (Advanced Inspection Technologies)Melbourne, United States
    Comment Share
  • Vivek Rohra
    Vivek Rohra registered the company Advanced Inpection Technologies (NDT / inspection service provider)
    1 month ago
    Community
    Comment Share
  • Jeffrey Tanis
    Jeffrey Tanis joined as Inspection Engineer
    1 month ago
    Community
    Comment Share
  • Aravind Subramani
    Aravind Subramani joined as Mechanical Engineer
    1 month ago
    Community
    Comment Share
  • JULIO HERNANDEZ
    JULIO HERNANDEZ joined as Inspector
    1 month ago
    Community
    Comment Share
  • Memphoo reyard
    Memphoo reyard joined as NDT Professional
    1 month ago
    Community
    Comment Share
  • Adnane Guerti
    Adnane Guerti posted a new vacancy, NDT Level 2 Inspectors – UT / MT / PT / VT - EN ISO 9712 - Whatsapp: +32488010871
    1 month ago
    Vacancy
    VacancyNDT Level 2 Inspectors – UT / MT / PT / VT - EN ISO 9712 - Whatsapp: +32488010871Talentris · Belgium
    Comment Share
  • Adnane Guerti
    Adnane Guerti registered the company Talentris - Technical Project Partner (NDT / inspection service provider)
    1 month ago
    Community
    Comment Share
  • Mark Gilmour
    Mark Gilmour posted an update in the group Visual Inspection
    1 month ago
    Update

    Weld inspection challenge: a 6 mm leg. But what is the throat?

    Use the left-hand sketch: a 90° equal-leg fillet weld with a straight, flat face and 6 mm legs. Do not include any additional penetration.

    What is its nominal throat thickness, approximately?

    A) 3.00 mm
    B) 4.24 mm
    C) 6.00 mm
    D) 8.49 mm

    What would you choose, and why? Add your reasoning below. My answer is below



    Answer: B) Approximately 4.24 mm.

    For the ideal equal-leg mitre fillet shown:
    a = z / √2 = 6 / √2 ≈ 4.24 mm.

    Here, z is the leg length and a is the nominal throat.

    The relationship relies on the stated geometry. Unequal legs, a different joint angle or a different face profile need appropriate assessment. Additional penetration must not simply be assumed.

    This calculation does not prove internal fusion or establish acceptance. Assess the actual weld against the drawing, applicable standard and approved procedure.

    More illustrated revision in NDT Pro Study Plus:
    ndt-pro-study-plus.pplx.app

    1792404130-VT-WI-LinkedIn
    Comment Share
  • Mark Gilmour
    Mark Gilmour joined the group Visual Inspection
    1 month ago
    Community
    Comment Share
  • Mark Gilmour
    Mark Gilmour posted an update in the group Visual Welding Inspection
    1 month ago
    Update

    Weld inspection challenge: a 6 mm leg. But what is the throat?

    Use the left-hand sketch: a 90° equal-leg fillet weld with a straight, flat face and 6 mm legs. Do not include any additional penetration.

    What is its nominal throat thickness, approximately?

    A) 3.00 mm
    B) 4.24 mm
    C) 6.00 mm
    D) 8.49 mm

    What would you choose, and why? Add your reasoning below. My answer is below



    Answer: B) Approximately 4.24 mm.

    For the ideal equal-leg mitre fillet shown:
    a = z / √2 = 6 / √2 ≈ 4.24 mm.

    Here, z is the leg length and a is the nominal throat.

    The relationship relies on the stated geometry. Unequal legs, a different joint angle or a different face profile need appropriate assessment. Additional penetration must not simply be assumed.

    This calculation does not prove internal fusion or establish acceptance. Assess the actual weld against the drawing, applicable standard and approved procedure.

    More illustrated revision in NDT Pro Study Plus:
    ndt-pro-study-plus.pplx.app

    1792403967-VT-WI-LinkedIn
    Comment Share
  • Mark Gilmour
    Mark Gilmour joined the group Visual Welding Inspection
    1 month ago
    Community
    Comment Share
  • Mark Gilmour
    Mark Gilmour joined the group Digital Radiography
    1 month ago
    Community
    Comment Share
  • Mark Gilmour
    Mark Gilmour joined the group Eddy Current (ECT)
    1 month ago
    Community
    Comment Share
  • Mark Gilmour
    Mark Gilmour posted an update in the group Dye Penetrant Inspection (PT) (DPI)
    1 month ago
    Update

    PT challenge: seven possible crack locations. One essential requirement.

    The illustration shows possible crack locations at weld toes, thread roots, fillets and other features.

    For liquid penetrant testing to reveal a crack in a suitable nonporous material, what must be true?

    A) The material must be ferromagnetic
    B) The crack must be completely below the surface
    C) The crack must have an opening accessible at the inspection surface
    D) The crack must run along the weld

    What would you choose, and why? Add your reasoning below. My answer is below.

    Answer: C) The crack must have an opening accessible at the inspection surface.

    Penetrant must be able to enter the discontinuity. PT cannot reveal a completely enclosed subsurface crack.

    An opening is necessary, but it does not guarantee detection. Contamination, coatings or smeared metal can obstruct entry, and preparation, dwell time, removal, development and viewing conditions all matter.

    The red traces illustrate possible locations, not a prediction that those features are cracked or a set of acceptance limits. Follow the approved procedure.

    More illustrated revision in NDT Pro Study Plus:
    ndt-pro-study-plus.pplx.app

    1792403704-PT-LinkedIn
    Comment Share
  • Mark Gilmour
    Mark Gilmour joined the group Dye Penetrant Inspection (PT) (DPI)
    1 month ago
    Community
    Comment Share
  • Mark Gilmour
    Mark Gilmour posted an update in the group Magnetic Particle Inspection (MPI) (MT)
    1 month ago
    Update

    MT challenge: a crack along the weld. Which way would you magnetise?

    Look at the two arrangements in the illustration. Consider the local magnetic field at the crack, assuming adequate field strength and suitable inspection conditions.

    Which field direction is most favourable for detecting the crack?

    A) Parallel to the crack
    B) Across the crack, approximately at right angles
    C) Either direction is equally favourable
    D) Field direction does not matter

    What would you choose, and why? Add your reasoning below. My answer is below

    Answer: B) Across the crack, approximately at right angles.

    Magnetic particle testing is most sensitive when the local magnetic field crosses the crack rather than running along it. In the illustration’s left-hand arrangement, the field crosses the longitudinal crack.

    This is why inspections commonly use two approximately perpendicular magnetisation directions when discontinuity orientation is unknown. Orientation alone does not demonstrate adequate field strength or coverage: follow the approved technique and required verification checks.

    More illustrated revision in NDT Pro Study Plus:
    ndt-pro-study-plus.pplx.app

    1792403600-MT-LinkedIn
    Comment Share
  • Mark Gilmour
    Mark Gilmour joined the group Magnetic Particle Inspection (MPI) (MT)
    1 month ago
    Community
    Comment Share
  • Mark Gilmour
    Mark Gilmour posted an update in the group General NDT Group
    1 month ago
    Update

    PT challenge: seven possible crack locations. One essential requirement.

    The illustration shows possible crack locations at weld toes, thread roots, fillets and other features.

    For liquid penetrant testing to reveal a crack in a suitable nonporous material, what must be true?

    A) The material must be ferromagnetic
    B) The crack must be completely below the surface
    C) The crack must have an opening accessible at the inspection surface
    D) The crack must run along the weld

    What would you choose, and why? Add your reasoning below. My answer is below.

    Answer: C) The crack must have an opening accessible at the inspection surface.

    Penetrant must be able to enter the discontinuity. PT cannot reveal a completely enclosed subsurface crack.

    An opening is necessary, but it does not guarantee detection. Contamination, coatings or smeared metal can obstruct entry, and preparation, dwell time, removal, development and viewing conditions all matter.

    The red traces illustrate possible locations, not a prediction that those features are cracked or a set of acceptance limits. Follow the approved procedure.

    More illustrated revision in NDT Pro Study Plus:
    ndt-pro-study-plus.pplx.app

    1792403347-PT-LinkedIn
    👍1
    Comment Share
  • PT. Jowo Land Construction
    PT. Jowo Land Construction joined as Other organisation
    1 month ago
    Community
    Comment Share
Sponsor of NDT InspectSponsors keep NDT Inspect free for its members