A visible IQI wire tells you something important, but not everything.
In a simplified wire-to-thickness example, a 0.20 mm IQI wire is visible through 10 mm of material.
What percentage ratio is that?
More importantly, does it guarantee that every 0.20 mm crack would also be detected?
My explanation is below. This is a principle question, not a complete code-compliance assessment.
Answer: 2%.
(0.20 ÷ 10) × 100 = 2%
But no, that does not guarantee detection of every crack of a comparable size. An IQI is an image-quality reference, not a universal minimum-defect-size guarantee.
Crack orientation, the radiation path through the discontinuity and image contrast affect detectability. The applicable technique, IQI selection and acceptance requirements still need to be met.
More revision questions and explanations in NDT Pro Study Plus. Free preview:
ndt-pro-study-plus.pplx.app
Explore the free preview of NDT Pro Study Plus, my independent revision app. The full library is subscription-based. -
-
-
-
-
CompanyVivek Rohra added a company listing, AIT Products, LLC (Advanced Inspection Technologies)1 month ago
-
CommunityVivek Rohra registered the company Advanced Inpection Technologies (NDT / inspection service provider)1 month ago
-
-
-
-
-
VacancyAdnane Guerti posted a new vacancy, NDT Level 2 Inspectors – UT / MT / PT / VT - EN ISO 9712 - Whatsapp: +324880108711 month ago
NDT Level 2 Inspectors – UT / MT / PT / VT - EN ISO 9712 - Whatsapp: +32488010871Talentris · Belgium
-
CommunityAdnane Guerti registered the company Talentris - Technical Project Partner (NDT / inspection service provider)1 month ago
-
Weld inspection challenge: a 6 mm leg. But what is the throat?
Use the left-hand sketch: a 90° equal-leg fillet weld with a straight, flat face and 6 mm legs. Do not include any additional penetration.
What is its nominal throat thickness, approximately?
A) 3.00 mm
B) 4.24 mm
C) 6.00 mm
D) 8.49 mm
What would you choose, and why? Add your reasoning below. My answer is below
Answer: B) Approximately 4.24 mm.
For the ideal equal-leg mitre fillet shown:
a = z / √2 = 6 / √2 ≈ 4.24 mm.
Here, z is the leg length and a is the nominal throat.
The relationship relies on the stated geometry. Unequal legs, a different joint angle or a different face profile need appropriate assessment. Additional penetration must not simply be assumed.
This calculation does not prove internal fusion or establish acceptance. Assess the actual weld against the drawing, applicable standard and approved procedure.
More illustrated revision in NDT Pro Study Plus:
ndt-pro-study-plus.pplx.app -
-
Weld inspection challenge: a 6 mm leg. But what is the throat?
Use the left-hand sketch: a 90° equal-leg fillet weld with a straight, flat face and 6 mm legs. Do not include any additional penetration.
What is its nominal throat thickness, approximately?
A) 3.00 mm
B) 4.24 mm
C) 6.00 mm
D) 8.49 mm
What would you choose, and why? Add your reasoning below. My answer is below
Answer: B) Approximately 4.24 mm.
For the ideal equal-leg mitre fillet shown:
a = z / √2 = 6 / √2 ≈ 4.24 mm.
Here, z is the leg length and a is the nominal throat.
The relationship relies on the stated geometry. Unequal legs, a different joint angle or a different face profile need appropriate assessment. Additional penetration must not simply be assumed.
This calculation does not prove internal fusion or establish acceptance. Assess the actual weld against the drawing, applicable standard and approved procedure.
More illustrated revision in NDT Pro Study Plus:
ndt-pro-study-plus.pplx.app -
-
-
-
PT challenge: seven possible crack locations. One essential requirement.
The illustration shows possible crack locations at weld toes, thread roots, fillets and other features.
For liquid penetrant testing to reveal a crack in a suitable nonporous material, what must be true?
A) The material must be ferromagnetic
B) The crack must be completely below the surface
C) The crack must have an opening accessible at the inspection surface
D) The crack must run along the weld
What would you choose, and why? Add your reasoning below. My answer is below.
Answer: C) The crack must have an opening accessible at the inspection surface.
Penetrant must be able to enter the discontinuity. PT cannot reveal a completely enclosed subsurface crack.
An opening is necessary, but it does not guarantee detection. Contamination, coatings or smeared metal can obstruct entry, and preparation, dwell time, removal, development and viewing conditions all matter.
The red traces illustrate possible locations, not a prediction that those features are cracked or a set of acceptance limits. Follow the approved procedure.
More illustrated revision in NDT Pro Study Plus:
ndt-pro-study-plus.pplx.app -
-
UpdateMark Gilmour posted an update in the group Magnetic Particle Inspection (MPI) (MT)1 month agoMT challenge: a crack along the weld. Which way would you magnetise?
Look at the two arrangements in the illustration. Consider the local magnetic field at the crack, assuming adequate field strength and suitable inspection conditions.
Which field direction is most favourable for detecting the crack?
A) Parallel to the crack
B) Across the crack, approximately at right angles
C) Either direction is equally favourable
D) Field direction does not matter
What would you choose, and why? Add your reasoning below. My answer is below
Answer: B) Across the crack, approximately at right angles.
Magnetic particle testing is most sensitive when the local magnetic field crosses the crack rather than running along it. In the illustration’s left-hand arrangement, the field crosses the longitudinal crack.
This is why inspections commonly use two approximately perpendicular magnetisation directions when discontinuity orientation is unknown. Orientation alone does not demonstrate adequate field strength or coverage: follow the approved technique and required verification checks.
More illustrated revision in NDT Pro Study Plus:
ndt-pro-study-plus.pplx.app -
-
PT challenge: seven possible crack locations. One essential requirement.
The illustration shows possible crack locations at weld toes, thread roots, fillets and other features.
For liquid penetrant testing to reveal a crack in a suitable nonporous material, what must be true?
A) The material must be ferromagnetic
B) The crack must be completely below the surface
C) The crack must have an opening accessible at the inspection surface
D) The crack must run along the weld
What would you choose, and why? Add your reasoning below. My answer is below.
Answer: C) The crack must have an opening accessible at the inspection surface.
Penetrant must be able to enter the discontinuity. PT cannot reveal a completely enclosed subsurface crack.
An opening is necessary, but it does not guarantee detection. Contamination, coatings or smeared metal can obstruct entry, and preparation, dwell time, removal, development and viewing conditions all matter.
The red traces illustrate possible locations, not a prediction that those features are cracked or a set of acceptance limits. Follow the approved procedure.
More illustrated revision in NDT Pro Study Plus:
ndt-pro-study-plus.pplx.app👍1 -