kevinmendoza1

kevinmendoza1

@kevinmendoza1 · joined Nov 2024 · active 1 year ago
NDT Level III
0 connections · 1 followers
  • kevinmendoza1
    kevinmendoza1 replied to a discussion
    1 year ago

    Terri,

    ASME BPVC.V Article 2 Section T-290 will detail the requirements.

    T-290 DOCUMENTATION

    T-291 RADIOGRAPHIC TECHNIQUE

    DOCUMENTATION DETAILS

    The organization shall prepare and document the

    radiographic technique details. As a minimum, the following

    information shall be provided.

    (a) the requirements of Article 1, T-190(a)

    (b) identification as required by T-224

    (c) the dimensional map (if used) of marker placement

    in accordance with T-275.3

    (d) number of exposures

    (e) X-ray voltage or isotope type used

    (f) source size (F in T-274.1)

    (g) base material type and thickness, weld thickness,

    weld reinforcement thickness, as applicable

    (h) source-to-object distance (D in T-274.1)

    (i) distance from source side of object to film (d in

    T-274.1)

    (j) film manufacturer and their assigned type/

    designation

    (k) number of film in each film holder/cassette

    (l) single- or double-wall exposure

    (m) single- or double-wall viewing

    T-292 RADIOGRAPH REVIEW FORM

    The Manufacturer shall be responsible for the preparation

    of a radiograph review form. As a minimum, the following

    information shall be provided.

    (a) a listing of each radiograph location

    (b) the information required in T-291, by inclusion of

    the information on the review form or by reference to

    an attached radiographic technique details sheet

    (c) evaluation and disposition of the material(s) or

    weld(s) examined

    (d) identification (name) of the Manufacturer’s representative

    who performed the final acceptance of the

    radiographs

    (e) date of Manufacturer’s evaluation


    Hope this helps.